Ordering information, Models, Software – Atec Fluke-2680 Series User Manual
Page 8: Accessories, Calibration
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa (31 40) 2 675 200 or
Fax (31 40) 2 675 222
In Canada (800)-36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com/
©2002 Fluke Corporation. All rights reserved.
Trademarks are the property of their respective owners.
Specifications subject to change without notice.
Printed in U.S.A. 3/2002 1638781 D-ENG-N Rev B
Fluke. Keeping your world
up and running.
Models
Model #
Description
2680A
Data Acquisition System Chassis
6 slots
2686A
Data Logging System Chassis
6 slots
ATA Flash memory drive
Includes 16 MB memory card
2680A-FAI*
Fast Analog Input Module
20 universal channels
50 V max isolation
16-bit resolution
1000 ch/sec scan rate
2680A-PAI*
Precision Analog Input Module
20 universal channels
300 V Max isolation
18-bit resolution
140 ch/sec scan rate
2680A-DIO*
Digital I/O and relay module (one per chassis),
20 digital input/outputs, 8 1-Amp contacts, 1 totalizer
*Includes universal input module or DIO connector module as appropriate
Software
Model #
Description
Fluke DAQ
Configuration software for Fluke 2680 Series and NetDAQ
Series.
(Included with purchase of 2680A, 2686A system chassis)
2680A-DEVSW
Indusoft Web Studio development software for Fluke DAQ
2680A-DLL
DLL Library for Fluke 2680 Series
2680A-OPC
OPC software for Fluke 2680 Series
Accessories
Model #
Description
2680A-180
Universal Input Module, extra connector
2680A-102
2680A-DIO connector module, extra connector
2620A-101
Shunt resistor set (12 ea), 10 ohm, .1%
2686A-800
16 MB ATA Flash memory card for Fluke 2686A
2686A-801
128 MB ATA Flash memory card for 2686A
2686A-802
256 MB ATA Flash memory card for 2686A
2686A-805
512 MB ATA Flash memory card for 2686A
2686A-810
1 GB ATA Flash memory card for 2686A
Y2680
19-inch rack mount kit for Fluke 2680 Series
Sample Order:
The following is a sample order for a data logger with 40 channels of analog
input and a digital output module.
Model #
Description
Quantity
2686A
Fluke 2686A Data Logging System Chassis
1
with 16 MB memory card
2680A-PAI
Precision Analog Input Module for Fluke 2680
1
Series, 20 channels
2680A-FAI
Fast Analog Input Module for Fluke 2680 Series,
1
20 channels
2680A-DIO
Digital output and relay alarm card for Fluke
1
2680 Series
Ordering Information
Calibration
Each analog input module comes
with a serialized Statement of
Calibration Practices and calibration
seal. Placement of modules between
chassis slots or between chassis
does not affect module calibration.
The chassis and 2680A-DIO do not
require calibration.
Sealed calibration is performed
via RS-232 port on the chassis.
Recommended 1-year calibration
cycle.