Measurement accuracy – Atec Fluke-2680 Series User Manual

Page 6

background image

6 Fluke Corporation Fluke 2680 Series Data Acquisition Systems

1

Total instrument accuracy for the indicated time period and ambient temperature
range. Includes A/D errors, linearization conformity, initial calibration error,
isothermality errors, reference junction conformity and power line voltage effects
within the range from 100VAC to 264VAC.

2

Sine wave inputs >2000 counts (slow), >200 counts (fast). Accuracies for crest
factor ≤2.0.

3

For two-wire measurements add 5Ω to basic accuracy (does not include lead-
wire resistances).

4

For two-wire measurements add 700-1000Ω to basic accuracy (does not include
lead-wire resistances). Ohms varies due to the resistance of the solid state
switches.

5

DIN/IEC 751 only, assumes no lead-wire resistance errors.

6

Resolution is 0.02°C or 0.04°F over the useful range of base metal thermocouples
(J, K, T, E, N, L, U) and 0.1°C or 0.2°F resolution for types R, S, B, and C with
slow scan.

7

Resolution is 0.2°C or 0.4°F over the useful range of base metal thermocouples (J,
K, T, E, N, L, U) and 1.0°C or 2.0°F resolution for types R, S, B, and C with slow
scan.

8

Accuracy for both slow and fast scan speeds.

9

Open thermocouple detection is performed on each thermocouple channel unless
defeated by computer command.

10

Using Stein hart – Hart thermistor polynomial: T = A+B (InR) + C (InR)

3

T = temp in °K
A, B and C = fitting constants
R = resistance of thermistor in Ω.

Measurement accuracy

cont.

Model 2680A-PAI

AC Voltage

Range

Resolution

Frequency

Accuracy

1,2

,3σ

σ

σ

σ

σ,± (% input+counts)

Slow

Fast

300 mV

1 µV

20 Hz-50 Hz

3.0%+25

6.0%+50

50 Hz-20 kHz

0.4%+25

1.0%+50

20 kHz-50 kHz

2.0%+30

3.0%+50

50 kHz-100 kHz

5.0%+50

5.0%+100

3V

100 µV

Same frequencies, similar accuracies as above

30V

1 mV

Same frequencies, similar accuracies as above

150/300V 10 mV

Same frequencies, similar accuracies as above

RTD (Pt 100)

Accuracy

1,5

, 3σ

σ

σ

σ

σ, ± °C (4-wire)

Temperature

Resolution

90 Day,

1 Year,

°C

°C

18 to 28°C

18 to 28°C

Slow

Slow

Slow

-200

0.003

0.06

0.09

0

0.003

0.09

0.13

100

0.003

0.10

0.16

300

0.003

0.14

0.21

600

0.003

0.19

0.30

Thermistor

10

2 k to 100 k

-40 °C to 150 °C

0.003

0.3

0.4

Frequency Measurement Accuracy

1,8

, -20 to 60°C

Range

Resolution

Accuracy, 3σ

σ

σ

σ

σ,± (% input +Hz)

Slow

Fast

Slow

Fast

15 Hz-900 Hz

0.01 Hz

0.1 Hz

0.05%+0.02 Hz

0.05%+0.2 Hz

900 Hz-9 kHz

0.1 Hz

1 Hz

0.05%+0.1 Hz

0.05%+1 Hz

9 kHz-90 kHz

1 Hz

10 Hz

0.05%+1 Hz

0.05%+10 Hz

90 kHz-900 kHz

10 Hz

100 Hz

0.05%+10 Hz

0.05%+100 Hz

1 MHz

100 Hz

1 kHz

0.05%+100 Hz

0.05%+1 kHz

Frequency Measurement Sensitivity (sine wave)

Frequency

Minimum Signal

Maximum Signal

15 Hz - 200 Hz

100 mV rms

150/300V rms

200 Hz - 70 kHz

100 mV rms

30V rms

70 kHz - 100 kHz

100 mV rms

20V rms

100 kHz - 200 kHz

150 mV rms

10V rms

200 kHz - 300 kHz

150 mV rms

7V rms

300 kHz - 1 MHz

linearly increasing from

linearly decreasing from

150 mV rms at 300 kHz to 7V rms at 300 kHz to
2V rms at 1 MHz

2V rms at 1 MHz

Model 2680A-FAI

AC Voltage

Range

Resolution

Frequency

Accuracy

1,2

,3σ

σ

σ

σ

σ,± (% input+counts)

Slow

Fast

300mV

10 µV

20 Hz-50 Hz

3.0%+25

6.0%+50

50 Hz-20 kHz

0.4%+25

1.0%+50

20 kHz-50 kHz

2.0%+30

3.0%+50

50 kHz-100 kHz

5.0%+50

5.0%+100

3V

100 µV

Same frequencies, similar accuracies as above

30V

1 mV

Same frequencies, similar accuracies as above

RTD (Pt 100)

Accuracy

1,5

, 3σ

σ

σ

σ

σ, ± °C (4-wire)

Temperature

Resolution

90 Day,

1 Year,

°C

°C

18 to 28°C

18 to 28°C

Slow

Slow

Slow

-200

0.03

0.16

0.25

0

0.03

0.20

0.31

100

0.03

0.23

0.34

300

0.03

0.30

0.41

600

0.03

0.53

0.63

Thermistor 10 k to 100 k

-40 °C to 150 °C

0.03

0.4

0.5

Frequency Measurement Accuracy

1,8

, -20 to 60°C

Range

Resolution

Accuracy, 3σ

σ

σ

σ

σ,± (% input +Hz)

Slow

Fast

Slow

Fast

15 Hz-900 Hz

0.01 Hz

0.1 Hz

0.05%+0.02 Hz

0.05%+0.2 Hz

900 Hz-9 kHz

0.1 Hz

1 Hz

0.05%+0.1 Hz

0.05%+1 Hz

9 kHz-90 kHz

1 Hz

10 Hz

0.05%+1 Hz

0.05%+10 Hz

90 kHz-900 kHz

10 Hz

100 Hz

0.05%+10 Hz

0.05%+100 Hz

1 MHz

100 Hz

1 kHz

0.05%+100 Hz

0.05%+1 kHz

Frequency Measurement Sensitivity (sine wave)

Frequency

Minimum Signal

Maximum Signal

15 Hz - 200 Hz

100 mV rms

30V rms

200 Hz - 70 kHz

100 mV rms

30V rms

70 kHz - 100 kHz

100 mV rms

20V rms

100 kHz - 200 kHz

150 mV rms

10V rms

200 kHz - 300 kHz

150 mV rms

7V rms

300 kHz - 1 MHz

linearly increasing from

linearly decreasing from

150 mV rms at 300 kHz to 7V rms at 300 kHz to
2V rms at 1 MHz

2V rms at 1 M