beautypg.com

Fm/am-1600s/csa – Atec IFR-Aeroflex-FMAM1600S User Manual

Page 4

background image

IFR Ltd, Longacres House, Norton Green Road, Stevenage, Herts

SG1 2BA, United Kingdom. E-mail: [email protected]

Tel: +44 (0) 1438 742200 Freephone UK: 0800 282 388 Fax: +44 (0) 1438 727601

IFR Americas, Inc., 10200 West York Street, Wichita, Kansas

67215-8999, USA. E-mail: [email protected]

Tel: +1 316 522 4981 Toll Free USA: 1 800 835 2352 Fax: +1 316 522 1360

As we are always seeking to improve our products, the information in this document gives only a general indication of the product capacity, performance and suitability, none of which shall form part of any

contract. We reserve the right to make design changes without notice. All trademarks are acknowledged. Parent Company IFR Systems, Inc. © IFR Ltd. 1999.

FM/AM-1600S/CSA

Part no. 46891-026

Revision A

FM/AM-1600S/CSA

4

http://www.ifrinternational.com

VOLTMETER (DC/AC)
Ranges

200 mV to 2000 V (full scale, decade sequence,

1 M

)

Maximum Input (DC)

1000 VDC

500 VAC

Resolution

3.5 digit (maximum resolution 0.1 mV on 200 mV

range)

Accuracy

±5% of full scale ± 1 count (AC, where ACV/kHz

<140)

±1% of full scale ± 1 count (DC)

Frequency

DC, 50 Hz to 20 kHz

Input Impedance

1 M

(±5%)

150

(±5%)

600

(±5%)

OHMMETER
Ranges
200

to 20 M

(full scale, decade sequence)

Resolution

3.5 digit (maximum resolution 0.1 on 200

range)

Accuracy

±5% or 0.1

(±1 count)

Current Meter (DC/AC)
Ranges

20 mA to 2 A (full scale, decade sequence, 20 A

maximum when using external shunt)

Resolution

3.5 digit (maximum resolution 0.01 mA on 20 mA

range)

Accuracy

±5 % or 0.1 mA ±1 count

Vertical BW

1 MHz (-3 dB)

Input Ranges

1 mV/Div to 50 V/Div (1-2-5 sequence, 8 divisions)

Max Input

200 V Peak

Accuracy

±5% of full scale

±10% of full scale (1 mV and 2 mV ranges)

Resolution

1 % of full scale/256 datapoints, 8 divisions

Coupling

AC, DC, GND

Horizontal Sweep Rate

1 µSec /Div to 100 mSec/Div (1-2-5 sequence, 10

divisions)

Accuracy

±1 % of full scale

Resolution

1 % of full scale/400 datapoints per sweep

External Input Impedance

1 M

(shunted by 27 pF nominal)

Internal Signal Routing

425 kHz IF

Demod Audio

Function Generator

SINAD/BER

RF Power

EXT MOD

Range

400 kHz to 999.9999 MHz

Frequency Span Range

1 kHz/Div to 100 MHz/Div plus Zero Scan

(10 divisions in a 1-2-5 sequence)

Accuracy

±5% of span width + timebase accuracy

Display

Log 10 dB/Div and 2 dB/Div

Vertical Resolution

Full scale/1 dB full scale

Displayed Range (Dynamic)

60 dB (0 dB attenuation, span <1 MHz/Div)

70 dB (0 dB attenuation, 1 kHz/Div, Ant connector)

Bandwidth Switching Error

<2 dB (5 kHz/Div thru 1 MHz/Div)

<3 dB (<5 kHz/Div or >1 MHz/Div)

Overall Accuracy

±4 dB (10 MHz to 400 MHz) (normalized)

±5 dB (>400 MHz to 2010 MHz) (normalized)

±2 dB Log Linearity

Input Attenuator

0 dB, 20 dB, 40 dB (User selectable, ANT Input

Port)

40 dB, 60 dB, 80 dB, (User selectable Pwr

2 W,

T/R Port)

60 dB, 80 dB, 100 dB, (User selectable, Pwr >2 W,

T/R)

Range

1 x 10

-1

to 1 x 10

-5

Data Rates

75, 150, 300, 600, 1200, 2400, 4800 bps and

16 kbps

Data Pattern Size

100 to 100,000 bits

Data Pattern Type

Random, Fixed and User Defined

IEEE 488.1-1987 Internally Assigned GPIB

Addresses

System Control Processor (GPIB Address=4)

TDMA Control Processor (GPIB Address=5)

RS-232 (Asynchronous) SCSI-1 External Video

Port Operation Mode

EGA Compliant

Frequency Reference Ports

BNC Input for External 10 MHz Sync

BNC Output of Internal 10 MHz Sync

IQ Output Interface

BNC Connector

TDMA Timeslot Sync

BNC Connector

Frequency Standard

10 MHz (Nominal)

Temp Stability

±0.01 ppm (0 to 50°C)

Ageing

±0.1 ppm per year

Dimensions

477 mm (18.8 in) wide, 187 mm (7.4 in) high,

635 mm (25 in) deep (with bail handle and front

panel cover in place, without CSA)

Weight

21.8 kg (48 lb) without CSA

(60 lb) with CSA

Operating Temperature Range

0 to 50°C

Line

85 - 135 to 180 - 260 VAC

50 to 400 Hz @ 200 W Maximum

170 W Typical

Type

Color, CRT 70° deflection, inline

Size

172 mm (6.8 in) diagonal, 142 mm (5.6 in) wide,

132 mm (5.2 in) high

Resolution

640 pixel x 350 pixels.

When ordering please quote the full ordering number

information

Ordering

Numbers

Versions

1600S

FM/AM-1600S Service Monitor

1600S-C

FM/AM-1600S Service Monitor with

Certificate of Calibration

CSA4

CSA4 (IS-54, GPIB, UWC-136, TDMA, 400

& 800 MHz)

CSA4-C

CSA4 (IS-54, GPIB, UWC-136, TDMA, 400

& 800 MHz) with Certificate of Calibration

1600SNAMPS FM/AM-1600S/CSA, NAMPS
1600SCSA4

CSA4 System (includes 1600S Service

Monitor CSA4 with IS-54, GPIB, UWC-136,

TDMA, 400 & 800 MHz) with Certificate of

Calibration

1600SCSA4-C CSA4 Systems (includes 1600S Service

Monitor and CSA4 with IS-54, GPIB,

UWC-136, TDMA, 400 & 800 MHz) with

Certificate of Calibration
Accessories

AC0300

TMAC User Manual

AC510 Paging

Encoder

AC1009

EasySpan for DOS (Waveform Transfer

Software)

AC1009W

EasySpan for Windows (Transfer Software)

AC1010

Easy-Com-FM (Land Mobile Test Software)

AC1011

EasyScan (Spectral Usage Software)(req.

AC9157)

AC1012

AutoCell-882 (Ericsson 882 Test

Software)(req. AC9157)

AC1017

AutoCell Series II (Lucent Series II Test)(req.

AC9157)

AC1018

AutoCell-Motorola (Motorola LD & HD

Test)(req. 1600SNAMPS and AC9157)

AC1019

EasySweep (Swept Antenna

Measurements)(req. AC9157)

AC1020D

AutoCell-NTD (NT/Novatel/GE/NTTRU)(req.

AC9157)

AC1021

CellScan Cellular Bar Graph RF Level Meter

(req. AC9157)

AC1036

UWC-136 Conformance Software

(req. CSA4)

AC1048

SSD Update & Authentication Test

(req. CSA4)

AC1201

Telescopic Antenna

AC4101

Return Loss Bridge (5 MHz to 1 GHz)

AC4102

Return Loss Bridge Kit (5 MHz to 1 GHz)

(includes AC1019)

AC4103

Return Loss Bridge Kit (5 MHz to

2 GHz) (includes AC1019)

AC8600

Maintenance Manual

AC8645

Microphone

AC9153

Carrying Case

AC9154

NT400 System Test (req. CSA4)

AC9155

AMPS Cellular System Analyzer

AC9156

AMPS Mobile Station Test

AC9157

2.5 MB FIle System

AC9158

Rubidium Time Base

EasyCom-FM, EasySweep, EasySpan, CellScan,

AutoCell and EasyScan are copyrighted by IFR

Systems, Inc.

Versions and Accessories

Display

Power Requirements

General Characteristics

Master Oscillator

Input/Output (I/O)

Bit Error Meter (BER)

Spectrum Analyzer

Oscilloscope

Digital Multimeter