beautypg.com

Fm/am-1600s/csa, Specification – Atec IFR-Aeroflex-FMAM1600S User Manual

Page 2

background image

capabilities, full level control and

measurement facilities of modulation, and

precision power meter features for

enhanced sensitivity and high accuracy

testing needs.

Analog paging encoding/decoding,

DTMF, tone coded squelch, digital squelch,

AM modulation/demodulation with two

separate AF generators and a cross band

duplex feature gives you added test

versatility in a variety of public and private

wireless systems.

Software Options Make Complex

Testing Simple

As with every IFR test set, you get the

advantage of IFR applications engineering

support.

Our comprehensive portfolio of

application software options is designed to

automate and expand the functionality of

your instrument.

Plus, on-going software support means

that you can easily upgrade your

FM/AM-1600S/CSA when standards

definitions or test and service requirements

change.

• AC1009W - EasySpan is a Windows-

based software utility which extracts

spectrum analyzer and tracking

generator traces from the IFR

FM/AM-1600S/CSA to a PC for further

off-line analysis.

• AC1011 - Simultaneously analyzes the

signal strength or channel activity of up

to three voice channel groups or 100

frequencies.

•

AC1012 - AutoCell 882 is a

comprehensive test package for Ericsson

model 882 base station transceivers.

• AC1017 - AutoCell-Series II is a

comprehensive program for FCC

compliance testing of Lucent Series II

cell sites.

• AC1018 - Provides automated testing

and calibration of Motorola HD-II/LD cell

sites.

• AC1019 - EasySweep is a swept

measurement utility designed to test

antennas and transmission lines.

• AC1020D - AutoCell NT and AutoCell

NTD provides automated testing of

Northern Telecom cell sites.

Dynamic IQ Constellation Display

Simplifies Analysis

The FM/AM-1600S/CSA provides you

with a dynamic, high speed constellation

display for precise RF modulation analysis

of

π

/4 DQPSK digitally modulated

waveforms from 10 MHz to 1 GHz. This

unique FM/AM-1600S/CSA feature gives a

near-real time display of digital modulation

characteristics that points out the cause of

the trouble in digital radios.

IQ Constellation display allows for comprehensive

digital modulation testing

Complex Functionality Made Easy

Even with its elaborate capabilities, the

FM/AM-1600S/CSA was developed to

execute complex tests simply and with

minimal operator training.

Using field-proven front panel and

user man-machine interfaces, the

FM/AM-1600S/CSA gives you the

performance and ease-of-use features that

significantly reduce your testing and

training time.

Its test macro command programming

language (TMAC) can be easily configured

to perform complex automatic tests on

base stations and terminals (including

single and multi-mode as well as single

and multi-band radios), and baseband

equipment. This powerful capability allows

you to create and save simple "one button"

test routines for future use. This flexibility

means you can create and execute

complex and repeatable routines no matter

what your level of expertise.

A color display gives FM/AM-1600S/CSA

users vivid screen clarity. Extensive use of

softkeys reduces your complex cellular and

PCS parametric and protocol tests to fast,

simple and manageable routines.

Specification

(T/R & DUPLEX CONNECTORS)
Frequency Range

400 kHz to 999.9999 MHz

Resolution

100 Hz

Accuracy

Same as Master Oscillator

Output Level Range (T/R)

-137 dBm to 0 dBm into 50

(-40 dBm maximum with reverse power present)

Duplex Level Range

-120 dBm to + 7 dBm or into 50

Duplex Resolution

0.1 dB

Level Accuracy (T/R)

±1.5 dB (level

-110 dBm)

±2.5 dB (levels from <-110 dBm to -127 dBm)

Duplex Level Accuracy

±1.5 dB (level

-100 dBm)

±2.5 dB (levels from <-100 dBm to -120 dBm)

VSWR (T/R)

<1.35:1 typical

Duplex VSWR

<1.38:1

INPUT PROTECTION
(T/R)

See RF Power Meter

(DUPLEX)

65 W (15 seconds with alarm)

SPECTRAL PURITY
Harmonics

<-26 dBc

Non-Harmonics

<-50 dBc

Residual FM

<10 Hz (RMS, 0.3 kHz to 3 kHz BW)

Residual AM

<0.05% (RMS, 0.3 kHz to 3 kHz BW)

SSB Phase Noise

<-90 dBc/Hz (25 kHz offset)

<-85 dBc/Hz (25 kHz offset, f

c

930 MHz)

<-80 dBc/Hz (25 kHz offset, f

c

<1 MHz)

Internal FM Range

Off, 100 Hz to 100 kHz Dev

Accuracy

±5% (1 kHz to 25 kHz Dev, 1 kHz rate)

±7% (<1 kHz Dev and >25 kHz Dev, 1 kHz rate)

Resolution

100 Hz (

25 kHz Dev)

500 Hz (>25 kHz Dev)

Rate

Off, 30 Hz to 40 kHz

(

20 kbs digital)

Waveforms

Sine, Square, Triangle, Ramp and Pulse

Distortion

<1 % (1 kHz rate, 0.3 kHz to 3 kHz BW,

1 kHz to 25 kHz deviation)

INTERNAL AM RF GENERATOR
Range

500 kHz to 999.9999 MHz

Internal AM Range

Off, 1% to 90%

Accuracy

±5% of setting (30% to 90% modulation, 1 kHz

sinewave)

±10% of setting (30% to 90% modulation, 1 kHz

sinewave f

c

< 1 MHz)

Resolution

1 %

Rate

100 Hz to 10 kHz

Waveforms

Sine, Square, Triangle, Ramp and Pulse

Distortion

<1% (30% to 70% modulation, 1 kHz sinewave, f

c

>1 MHz, 0.3 kHz to 3 kHz BW)

Internal Phase Modulation Range

Off, 0.1 to 10 Radians

Accuracy

±10% (at 1 kHz rate, > 0.3 Rad)

Resolution

0.1 Radians

Rate

Off, 30 Hz to 6 kHz

Waveforms

Sine, Square, Triangle, Ramp and Pulse

Distortion

<2% (1 kHz rate, 0.3 kHz to 3 kHz BW,

0.5 Rad)

External

External inputs with the same characteristics as the

internal modulation sources are supported.

A 10 Vp-p injection level is required to obtain

indicated setting ±10%.

Modulation

RF Signal Generator

FM/AM-1600S/CSA

FM/AM-1600S/CSA

2

http://www.ifrinternational.com