beautypg.com

Axs-100 series, Handheld otdr, Specifications – Atec EXFO-AXS-100 User Manual

Page 7: Optional power meter, General specifications

background image

AXS-100 Series

Handheld OTDR

LASER SAFETY

21 CFR 1040.10 AND IEC 60825-1:1993+A2:2001
CLASS 1M WITHOUT VFL OPTION
CLASS 3R WITH VFL OPTION

LASER RADIATION

AVOID DIRECT EYE EXPOSURE

CLASS 3R LASER PRODUCT

IEC 60825-1:1993+A2:2001

21 CFR 1040.10

λ:

650

±

10 nm

Pout maximum < 5mW (into free space)

www.EXFO.com

Notes

a

All specifications valid at 23 °C ± 2 °C (73.4 °F ± 3.6 °F) with an FC/PC connector, unless
otherwise specified.

b. Typical dynamic range with longest pulse and three-minute averaging at SNR = 1.

Multimode dynamic range is specified for 62.5

μm fiber; a 3 dB reduction is seen

when testing 50

μm fiber.

c. Typical dead zone for multimode reflectance below – 35 dB and singlemode reflectance

below –45 dB, using shortest pulse.

d. For multimode port, controlled launch conditions allow 50

μm and 62.5 μm multimode fiber testing.

e. Does not include uncertainty due to fiber index.

f.

Typical output power is given at 1300 nm for multimode output and 1550 nm for singlemode
output.

g. At 23 ºC ± 1 ºC, 1550 nm and with FC connector. With OTDR in idle mode, battery operated.

h. For ± 0.05 dB, from 18 ºC to 28 ºC.

SPECIFICATIONS

a

Wavelength (nm)

1310/1550/1625

850/1300/1310/1550

Dynamic range

b

(dB)

29/28/28 (1310/1550/1625)

24/25/32/30 (850/1300/1310/1550)

Pulse width (ns)

10, 30, 100, 275, 1000, 2500, 10 000

Multimode: 5, 10, 30, 100, 275, 1000
Singlemode: 5, 10, 30, 100, 275, 1000, 2500, 10 000

Event dead zone

c

(m)

2.5

0.8

Attenuation dead zone

c

(m)

11/12/12

3.5/4.5/4/4.5

Launch conditions

d

Class CPR 1 or 2

Linearity (dB/dB)

± 0.05

± 0.03

Loss threshold (dB)

0.05

0.01

Loss resolution (dB)

0.01

0.01

Sampling resolution (m)

0.16 to 5

Multimode: 0.08 to 2.5
Singlemode: 0.08 to 5.0

Sampling points

Up to 30 000

Up to 64 000

Distance uncertainty

e

(m)

± (1 + 0.005 % x distance + sampling resolution)

± (0.75 + 0.0025 % x distance + sampling resolution)

Distance range (km)

0.65 to 160

Multimode: 0.1 to 40
Singlemode: 0.65 to 260

Typical real-time refresh (Hz)

2

4

Memory capacity

500 traces

500 traces

Measurement time

User-defined

User-defined

Stable source output power

f

(dBm)

–9

Multimode: –1.5
Singlemode: -6.5

Visual fault locator (optional)

Laser, 650 nm ± 10 nm

Laser, 650 nm ± 10 nm

CW Typical Pout in 62.5/125 µm: 3 dBm (2 mW)

CW Typical Pout in 62.5/125 µm: 3 dBm (2 mW)

OPTIONAL POWER METER

g

Calibrated wavelengths (nm)

850, 1270, 1290, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490,
1510, 1530, 1550, 1570, 1590, 1610, 1625

Power range (dBm)

26 to –64 (GeX 2 mm)

Uncertainty

±5 % ± 0.4 nW (up to 5 dBm)

Display resolution (dB)

0.01 (–54 dBm to P

max

)

0.1 (–54 dBm to –64 dBm)
1 (–64 dBm to min)

Automatic offset nulling range

h

Maximum power to —38 dBm

Tone detection (Hz)

270/1000/2000

GENERAL SPECIFICATIONS

Size (H x W x D)

250 mm x 125 mm x 75 mm (9

7

/

8

in x 4

15

/

16

in x 3 in)

Weight

1 kg (2.2 lb)

Temperature

operating

–18 °C to 50 °C (14 °F to 122 °F)

storage

–40 °C to 70 °C (–40 °F to 158 °F)

Relative humidity

0 % to 95 % non-condensing

Power

Li-ion batteries 8 hours of continuous operation as per Bellcore TR-NWT-001138

Warranty (years)

1

AXS-100