Axs-100 series, Handheld otdr, Specifications – Atec EXFO-AXS-100 User Manual
Page 7: Optional power meter, General specifications

AXS-100 Series
Handheld OTDR
LASER SAFETY
21 CFR 1040.10 AND IEC 60825-1:1993+A2:2001
CLASS 1M WITHOUT VFL OPTION
CLASS 3R WITH VFL OPTION
LASER RADIATION
AVOID DIRECT EYE EXPOSURE
CLASS 3R LASER PRODUCT
IEC 60825-1:1993+A2:2001
21 CFR 1040.10
λ:
650
±
10 nm
Pout maximum < 5mW (into free space)
www.EXFO.com
Notes
a
All specifications valid at 23 °C ± 2 °C (73.4 °F ± 3.6 °F) with an FC/PC connector, unless
otherwise specified.
b. Typical dynamic range with longest pulse and three-minute averaging at SNR = 1.
Multimode dynamic range is specified for 62.5
μm fiber; a 3 dB reduction is seen
when testing 50
μm fiber.
c. Typical dead zone for multimode reflectance below – 35 dB and singlemode reflectance
below –45 dB, using shortest pulse.
d. For multimode port, controlled launch conditions allow 50
μm and 62.5 μm multimode fiber testing.
e. Does not include uncertainty due to fiber index.
f.
Typical output power is given at 1300 nm for multimode output and 1550 nm for singlemode
output.
g. At 23 ºC ± 1 ºC, 1550 nm and with FC connector. With OTDR in idle mode, battery operated.
h. For ± 0.05 dB, from 18 ºC to 28 ºC.
SPECIFICATIONS
a
Wavelength (nm)
1310/1550/1625
850/1300/1310/1550
Dynamic range
b
(dB)
29/28/28 (1310/1550/1625)
24/25/32/30 (850/1300/1310/1550)
Pulse width (ns)
10, 30, 100, 275, 1000, 2500, 10 000
Multimode: 5, 10, 30, 100, 275, 1000
Singlemode: 5, 10, 30, 100, 275, 1000, 2500, 10 000
Event dead zone
c
(m)
2.5
0.8
Attenuation dead zone
c
(m)
11/12/12
3.5/4.5/4/4.5
Launch conditions
d
Class CPR 1 or 2
Linearity (dB/dB)
± 0.05
± 0.03
Loss threshold (dB)
0.05
0.01
Loss resolution (dB)
0.01
0.01
Sampling resolution (m)
0.16 to 5
Multimode: 0.08 to 2.5
Singlemode: 0.08 to 5.0
Sampling points
Up to 30 000
Up to 64 000
Distance uncertainty
e
(m)
± (1 + 0.005 % x distance + sampling resolution)
± (0.75 + 0.0025 % x distance + sampling resolution)
Distance range (km)
0.65 to 160
Multimode: 0.1 to 40
Singlemode: 0.65 to 260
Typical real-time refresh (Hz)
2
4
Memory capacity
500 traces
500 traces
Measurement time
User-defined
User-defined
Stable source output power
f
(dBm)
–9
Multimode: –1.5
Singlemode: -6.5
Visual fault locator (optional)
Laser, 650 nm ± 10 nm
Laser, 650 nm ± 10 nm
CW Typical Pout in 62.5/125 µm: 3 dBm (2 mW)
CW Typical Pout in 62.5/125 µm: 3 dBm (2 mW)
OPTIONAL POWER METER
g
Calibrated wavelengths (nm)
850, 1270, 1290, 1310, 1330, 1350, 1370, 1390, 1410, 1430, 1450, 1470, 1490,
1510, 1530, 1550, 1570, 1590, 1610, 1625
Power range (dBm)
26 to –64 (GeX 2 mm)
Uncertainty
±5 % ± 0.4 nW (up to 5 dBm)
Display resolution (dB)
0.01 (–54 dBm to P
max
)
0.1 (–54 dBm to –64 dBm)
1 (–64 dBm to min)
Automatic offset nulling range
h
Maximum power to —38 dBm
Tone detection (Hz)
270/1000/2000
GENERAL SPECIFICATIONS
Size (H x W x D)
250 mm x 125 mm x 75 mm (9
7
/
8
in x 4
15
/
16
in x 3 in)
Weight
1 kg (2.2 lb)
Temperature
operating
–18 °C to 50 °C (14 °F to 122 °F)
storage
–40 °C to 70 °C (–40 °F to 158 °F)
Relative humidity
0 % to 95 % non-condensing
Power
Li-ion batteries 8 hours of continuous operation as per Bellcore TR-NWT-001138
Warranty (years)
1
AXS-100
AXS-110