beautypg.com

Ordering information, Safety, Fot-93 x - xx - xx - xx - x - xx – Atec Exfo-FOT-932X User Manual

Page 8

background image

Model
FOT-93

2

= Ge detector, dual-wavelength 1310/1550 nm

FOT-93

2-4

= Ge detector, triple-wavelength 1310/1550/1625 nm

FOT-93

2-5

= Ge detector, triple-wavelength 1310/1490/1550 nm

FOT-93

2X

= GeX detector, dual-wavelength 1310/1550 nm

FOT-93

2X-4

= GeX detector, triple-wavelength 1310/1550/1625 nm

FOT-93

2X-5

= GeX detector, triple-wavelength 1310/1490/1550 nm

FOT-93

3

= InGaAs detector, dual-wavelength 1310/1550 nm

FOT-93

3-4

= InGaAs detector, triple-wavelength 1310/1550/1625 nm

FOT-93

3-5

= InGaAs detector, triple-wavelength 1310/1490/1550 nm

FOT-93

X

-

XX

-

XX

-

XX

-

X

-

XX

Ordering Information

Safety

21 CFR 1040.10 and IEC 60825-1:1993+A1:1997+A2:2001:
Emitters used for sources, FasTesT, ORL and talk set
CLASS 1 LASER PRODUCT
CLASS 1 LED PRODUCT
The FOT-930’s optional VFL is a Class 3R laser product. Output power level is lower than the maximum specified on label.
Refer to specifications for output power.


If VFL option is available

QS

LASER RADIATION

AVOID DIRECT EYE EXPOSURE

CLASS 3R LASER PRODUCT

IEC 60825-1:1993+A2:2001

21 CFR 1040.10

λ:

650

±

10 nm, Pout maximum: 5mW

CORPORATE HEADQUARTERS

400 Godin Avenue

Vanier (Quebec) G1M 2K2 CANADA

Tel.: 1 418 683-0211 · Fax: 1 418 683-2170

EXFO AMERICA

4275 Kellway Circle, Suite 122

Addison TX 75001 USA

Tel.: 1 800 663-3936 · Fax: 1 972 836-0164

EXFO EUROPE

Le Dynasteur, 10/12 rue Andras Beck

92366 Meudon la Forêt Cedex FRANCE

Tel.: +33.1.40.83.85.85 · Fax: +33.1.40.83.04.42

EXFO ASIA-PACIFIC

151 Chin Swee Road, #03-29 Manhattan House

SINGAPORE 169876

Tel.: +65 6333 8241 · Fax: +65 6333 8242

EXFO CHINA

Beijing New Century Hotel Office Tower, Room 1754-1755

Beijing 100044 P. R. China

Tel.: +86 (10) 6849 2738 · Fax: +86 (10) 6849 2662

No. 6 Southern Capital Gym Road

TOLL-FREE (USA and Canada)

Tel.: 1 800 663-3936

www.exfo.com

[email protected]

SPFOT930.1AN © 2004 EXFO Electro-Optical Engineering Inc. All rights reserved. Printed in Canada 04/02

EXFO is certified ISO 9001 and attests to the quality of these products. EXFO has made every effort to ensure that the information contained
in this specification sheet is accurate. However, we accept no responsibility for any errors or omissions, and we reserve the right to modify design,
characteristics and products at any time without obligation.

Units of measurement in this document conform to SI standards and practices.

Contact EXFO for prices and availability or to obtain the phone number of your local EXFO distributor.
For the most recent version of this spec sheet, please go to the EXFO website at http://www.exfo.com/support/techdocs.asp
In case of discrepancy, the Web version takes precedence over any printed literature.

Second Source

00

= Without second source

12C

= 850/1300 nm LED 50/125 µm

2

12D

= 850/1300 nm LED 62.5/125 µm

2

Talk set and Visual Fault Locator

00

= Without talk set and VFL

VFT

= With talk set and VFL

3

(Universal 2.5 mm connector)

Connector
EI-EUI-

28

= UPC/DIN 47256

EI-EUI-

76

= UPC/HMS-10/AG

EI-EUI-

89

= UPC/FC narrow key

EI-EUI-

90

= UPC/ST

EI-EUI-

91

= UPC/SC

EI-EUI-

95

= UPC/E-2000

EA-EUI-

28

= APC/DIN 47256

1

EA-EUI-

89

= APC/FC narrow key

1

EA-EUI-

91

= APC/SC

1

EA-EUI-

95

= APC/E-2000

1

Software Language

A

= English

C

= Simplified Chinese

E

= Spanish

F

= French

G

= German

X

= Czech

Fiber Inspection Probe

00

= Without probe

FP0

= Probe option and connection cable

FP1

= Probe connection cable and 200x probe

4

FP5

= Probe connection cable and 400x probe

4

Example: FOT-932-4-12C-FP1-A-EI-EUI-89

Notes

1. Not available with second source
2. Only available with Ge detector
3. Not available with second source and triple-wavelength
4. Comes with FIPT-U25M for 2.5 mm connectors, and FIPT-FC and FIPT-SC for bulkhead connectors