Personal and area monitors, Narda, Model selection guide – Atec Narda-A8860-A8862-A8864 User Manual
Page 5

Personal and Area Monitors
50 Years of
RF Safety
Test Solutions
USA TEL: (1) 631 231-1700 • FAX: (1) 631 231-1711 • E-MAIL: [email protected] • www.narda-sts.com
GERMANY TEL: 49-7121-9732-777 • FAX: 49-7121-9732-790 • E-MAIL: [email protected] • www.narda-sts.de
an
communications company
narda
Safety Test Solutions
There are four series of Nardalert XT RF monitors. Within
each series, the specifications are essentially identical ex-
cept for the sensor “shaping.” Each specific standard or
guidance requires some differences in the sensor design
and calibration. The four Nardalert XT series are:
8860 Series:
This is the full-featured, Nardalert XT series that includes all
the user-adjustable parameters plus the ability to log more
than 30,000 data points automatically whenever the moni-
tor is turned on. The data-logger feature can be used to an-
alyze personnel exposures in order to improve operations.
Or it can be used in the way a Flight Data Recorder is used
on board an aircraft – the logged data can be reviewed
whenever there is a need to determine an individual's level
of exposure.
8861 Series:
The 8861 Series is designed for applications where the
user will be in close proximity to strong ELF fields, such as
from 50/60 Hz power lines. These monitors are very similar
to the standard, full-featured series except that the inside
of the housing has a special conductive coating that
blocks the ELF signals. The low frequency range of these
monitors is reduced by the coating.
8862 Series:
This series is identical to the full-featured 8860 Series ex-
cept they do not include the data-logging capability.
8864 Series:
This series is identical to the full-featured 8860 Series with
one exception: these high power monitors function at field
levels five times higher than all other model series.
Soft cases are recommended for use by climbers
and in severe weather: (l. to rt.) climber-harness
case; case front; belt-clip case
Model Selection Guide
STANDARD / GUIDANCE
NARDALERT XT MODELS
8860 SERIES
8861 SERIES
8862 SERIES
8864 SERIES
ACGIH
B8860
B8861
B8862
B8864
AS/NZ 2772.1 (1998, draft)
Occupational
D8860
D8861
D8862
D8864
Canada Safety Code 6 99-EHD-237
RF / Microwave Worker
C8860
C8861
C8862
C8864
DIN VDE 0848, Part 2, October 1991 Area 1
Occupational
D8860
D8861
D8862
D8864
ENV 50166-2
Occupational
D8860
D8861
D8862
D8864
FCC 1997
Occupational / Controlled
A8860
A8861
A8862
A8864
ICNIRP 1998
Occupational
D8860
D8861
D8862
D8864
IEEE C95.1-1999/ANSI C95.1-1992
Controlled
B8860
B8861
B8862
B8864
Japan RCR-38
Controlled
A8860
A8861
A8862
A8864
NATO STANAG 2345
B8860
B8861
B8862
B8864
ÖNORM S 1120, 1992
Occupational
A8860
A8861
A8862
A8864