beautypg.com

Specifi cations, Continued) – Atec Agilent-N9343C User Manual

Page 5

background image

5

Specifi cations

(continued)

Amplitude specifications (continued)

Supplemental information

Level display range (continued)

Trace functions

Clear/write, maximum hold,
minimum hold, average

Level measurement error

1 MHz to 7 GHz

Excluding input VSWR mismatch
± 1.3 dB

• 20 to 30 °C, 30 to 70% RH, peak

detector, preamp off, input signal
-50 to 0 dBm, 95% percentile

• Swp Time Rule is set to Accuracy
• Adds additional ± 0.3 dB when Swp

Time Rule is set to Speed

7 to 13.6 GHz

± 1.6 dB

Reference level

2

Setting range

-100 to +30 dBm

Steps of 1 dB

Setting resolution

Log scale

0.01 dB

Linear scale

Same as log (2.236 µV to 7.07 V)

Accuracy

0

RF input VSWR (at tuned frequency)

10 MHz to 3 GHz

1 MHz to 7 GHz

< 1.5:1

Nominal, ≥ 10 dB attenuation

7 to 13.6 GHz

< 2:1

Spurious response

Second harmonic
distortion

< -65 dBc, typical < -70 dBc,
50 MHz to 7 GHz

Mixer signal level at -30 dBm, input
attenuation 0 dB, preamp off,
20 to 30 °C

< -80 dBc, typical < -90 dBc,
7 to 13.6 GHz

Third order intermodulation
distortion (third order
intercept)

+8 dBm, typical +9 dBm,
50 to 300 MHz

Two -20 dBm tones at input mixer,
spaced by 100 kHz, input attenuation
0 dB, preamp off, reference level
≥ -30 dBm, 20 to 30 °C

+9 dBm, typical +11 dBm,
300 MHz to 8 GHz

+10 dBm, typical +12 dBm,
8 to 13.6 GHz

Input related spurious

< -60 dBc, typical < -70 dBc

• -30 dBm signal at input mixer, span

< 2.9 GHz

• Exception:

-55 dBc (2 x F1 = center frequency
-5,890 MHz, 7 GHz < center frequency
< 10 GHz, with F1 input frequency)

Inherent residual response

< -95 dBm, typical -110 dBm,
1 MHz to 7 GHz

Input terminated and 0 dB RF
attenuation, preamplifier off

< -85 dBm, typical -93 dBm,
7 to 13.6 GHz

2. Reference level only affects the display not the measurement, so trace data markers do not cause additional errors in measurement results.