Frequency analysis
A/D converter
24 bits of precision.
Automatic Integrator Correction
Allows precise measurement of low frequency vibrations down to 0.2 Hz.
Averaging modes
Normal, exponential, peak hold, order tracking, negative averaging, synchronous time
Cursors Spectrum
Single, Harmonic, Moving Harmonic, Sideband, and Time/Frequency for waveform.
Dynamic range
Converter has 120 dB dynamic range.
Frequency range
DC to 10 Hz minimum, DC to 80 kHz maximum
Frequency Units
Hz, CPM, Orders.
Full-scale range
Accelerometer input: 0-20V, Volts input -20V + 20V
Noise floor
Typically less than 20 μV for a 400-line spectrum at 1000 Hz maximum frequency.
Number of averages
5,000 in Route mode, 10,000 in Job mode.
Resolution
100, 200, 400, 800, 1600, 3200, 6400, or 12800 lines of resolution. True Zoom provides
effective resolution of up to 300,000 lines.
Response
Flat to DC for non-integrated and DC-coupled signals; optional AC coupling -3 dB at 1 Hz
Scaling
Linear or Log, both X and Y.
Windows
Hanning or uniform
Data storage capacity
Internal memory
1 GB
External memory
SD (Secure Digital). Virtually unlimited memory with off the shelf SDHC SD cards up to
32 GB.
Data analysis speed
400 line, 1000 HZ spectrum
67% overlap 6 avg/sec
1600 line, 1000 Hz spectrum
67% overlap 3 avg/sec
Measurement specifications