CSI 2140 Machinery Health Analyzer
June 2013
The 4-Channel Advantage
While the CSI 2140 is available in 1- and 2-channel options, it
is the 4-channel option that delivers the most advantages to
a predictive maintenance program. The CSI 2140 is already
30% faster than the CSI 2130 (the fastest data collector in the
industry to date) when collecting a measurement point. With
4-channel capabilities, speed through the data collection
route is increased even more. And unlike other 4-channel units
on the market, the CSI 2140 delivers all four channels when
you need them the most – critical equipment startup and
troubleshooting diagnostics.
Monitor More Machines in Less Time Using True 4-Channel.
Using a triaxial accelerometer, the CSI 2140 simultaneously
collects vertical, horizontal, and axial readings on a bearing.
Place the sensor on the measurement point, press the button,
and when collection is complete move on to the next bearing.
Data collection time is reduced by as much as 30% compared
to the CSI 2130, and even more when compared to other
vibration collectors. Faster data collection translates into
less time in harsh or hazardous environments, more machines
monitored, and more time dedicated to higher value tasks like
analysis and diagnostics.
4-Channel Data Collection Enables Powerful Diagnostic
Options. Perform additional advanced diagnostics and deeper
dive diagnostic tests using 4-channel collection. With 4-channel
monitoring, you will gain additional data and diagnostic tools
to help you identify the root cause of your toughest equipment
problems. For example,
n
View dual orbit plots, one on either side of the coupling or
dual orbit/shaft centerline plots of both sleeve bearings on a
turbine, fan, or other production asset to see how the shaft is
moving in relation to the bearing races.
n
Collect ODS Modal data 66% faster to animate physical
movement of machinery, an important tool in identifying
the root cause of chronic or complex machinery problems.
Having the information you need for advanced diagnostics
faster allows you to move more quickly towards identifying
machinery faults or determining if it is safe to continue startup
of turbo machinery.
www.assetweb.com
2
scenario
Where is the Vibration Coming From: Coherence
Testing in One Step
Today is your first chance to use the new CSI 2140
Machinery Health Analyzer with four-channel data
collection capabilities to collect route data on the eight
critical motor/pumps that drive 80% of your production.
On pump #3, you notice some unusual vibration readings.
Is this a problem in motor/pump #3, or something else?
Last month there was high vibration levels in pump #5 –
you remember because you spent hours trying to find and
fix the problem and ended up missing the game on TV that
night. Turned out that motor/pump #5 – vibration from
motor/pump #6 was being transferred to #5 If coherence
testing had been an efficient option with your old analyzer,
you would have known how to find the true source of the
vibration and gotten home on time.
Here you are today with the power of four-channel data
collection in your hands. You can perform coherence
testing of motor/pump #3 and its neighbors in just two
minutes. You already have a sensor attached to motor/
pump #3, so you attach a sensor to each of its neighbors.
Pressing Enter on the analyzer shows you the results.
There is no coherence among the motor vibrations.
Number three is truly the motor you need to address.