7796 Datasheet

Information subject to change.

1/28/2013

Communication Capabilities

Current Monitor: ± 1V / 20A ±1%
Voltage Monitor: ± 1V / 1V ±1%
Reporting:
System Fault, OverTemp, Over Voltage,
Overload
Control:
Force to Standby; Reset after a fault

Protection

Over/Under Voltage:
± 10% from specified supply voltage
amplifier is forced to Standby

Over Current:
Breaker protection on both main
power and low voltage supplies

Over Temperature:
Separate Output transistor, heat sink,
and transformer temperature
monitoring and protection

Physical Characteristics

Chassis:
All aluminum construction designed for stand-alone or rack-
mounted operation with black chassis; the amplifier occupies
seven EIA 19-inch-wide rack units

Weight:
153 lbs. (69 kg)

AC Power:
Three-phase, 208 VAC ±10%, 47-60 Hz, 30A AC service. (400 VAC
+/-10%, 20A version available)

Operating Temperature:
10°C to 50°C (50°F to 122°F), Maximum Output Power de-rated
above 30°C (86°F).)

Humidity:
70% or less, non-condensing

Cooling:
Forced air-cooling from front to back through removable filters via
six 100 ft

3

/min. fans. No space is required between rack-mounted

amplifiers. Air filters are removable from the rear via one fastener
per side and may be eliminated if cabinet filtration is provided.

Dimensions:
19 in. x 22.8 in. x 12.25 in. (48.3 cm x 57.9 cm x 31.1 cm). Unite
occupies seven EIA 19-inch-wide rack units.