Communication Capabilities
Current Monitor: ± 1V / 20A ±1%
Voltage Monitor: ± 1V / 1V ±1%
Reporting:
System Fault, OverTemp, Over Voltage,
Overload
Control:
Force to Standby; Reset after a fault
Protection
Over/Under Voltage:
± 10% from specified supply voltage
amplifier is forced to Standby
Over Current:
Breaker protection on both main
power and low voltage supplies
Over Temperature:
Separate Output transistor, heat sink,
and transformer temperature
monitoring and protection
Physical Characteristics
Chassis:
All aluminum construction designed for stand-alone or rack-
mounted operation with black chassis; the amplifier occupies
seven EIA 19-inch-wide rack units
Weight:
153 lbs. (69 kg)
AC Power:
Three-phase, 208 VAC ±10%, 47-60 Hz, 30A AC service. (400 VAC
+/-10%, 20A version available)
Operating Temperature:
10°C to 50°C (50°F to 122°F), Maximum Output Power de-rated
above 30°C (86°F).)
Humidity:
70% or less, non-condensing
Cooling:
Forced air-cooling from front to back through removable filters via
six 100 ft
3
/min. fans. No space is required between rack-mounted
amplifiers. Air filters are removable from the rear via one fastener
per side and may be eliminated if cabinet filtration is provided.
Dimensions:
19 in. x 22.8 in. x 12.25 in. (48.3 cm x 57.9 cm x 31.1 cm). Unite
occupies seven EIA 19-inch-wide rack units.
AE Techron Sales Representative