7796 dc power, 7796 temperature over time – Atec AE-Techron-7796 User Manual
Page 2
7796 Datasheet
Information subject to change.
1/28/2013
AC Specifications
PEAK OUTPUT
RMS OUTPUT
40mSec Pulse,
30% Duty Cycle
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
5 Minute,
100% Duty Cycle
1 Hour,
100% Duty Cycle
Ohms
Volts
Amps
Volts
Amps
Volts
Amps
Volts
Amps
Volts
Amps
Watts
Open
181
0
181
0
181
0
128
0
128
0
0
16
159
12
159
10
159
10
112
7
112
7
795
8
159
19
154
19
154
19
109
13
109
13
1483
4
158
39
152
38
152
38
107
27
107
27
2887
2
157
79
141
71
100
50
5004
1.5
148
99
71
71
50
50
2509
1
140
140
71
71
50
50
2509
0.5
106
209
63
127
45
90
3999
0.25
53
209
Note: Performance levels typical up to 20 kHz frequency levels. Above 20 kHz, slew rate may affect
performance, reducing
maximum voltage, current and power output.
8 ohm Power Response:
DC-50 kHz: ± 150 Vpk
DC-150 kHz: ± 50 Vpk
DC-200 kHz: ± 25 Vpk
Maximum Continuous Output Power:
6600 watts RMS
Slew Rate:
41 V/μSec
Phase Response:
±8.3 degrees (10 Hz – 10 kHz)
Phase Error:
±0.1 degrees at 60 Hz
Maximum Continuous Output
Power:
6600 watts RMS
Output Offset:
7796: Less than 5 mV, field adjustable
to less than 1 mV
Unit to Unit Phase Error:
±0.1 degrees at 60Hz
Output Offset:
7796: Less than 5 mV, field adjustable
to less than 1 mV
7796P: Less than 200
V
Output Offset Current:
Less than 10 milliamperes DC
0
20
40
60
80
100
120
140
0
3
6
9
12 15 18 21 24
D
e
gr
e
e
s
C
Minutes
7796 DC Power
Thermal Limit
43 Volts 60 Amps
60 Volts 60 Amps
0
20
40
60
80
100
120
140
0
5 10 15 20 25 30 35 40 45 50
D
e
gr
e
e
C
Time in Minutes
7796 Temperature Over Time
Thermal