beautypg.com

Atec AE-Techron-7224 User Manual

Page 4

background image

7224 Datasheet

Information subject to change.

1/28/2013

Two 7224s in Series

High Voltage

Low Current

5 Min, 30% duty Cycle

1 Hr, 100% duty Cycle

Ohms

Volts Peak

Amps Peak

Volts Peak

Amps Peak

32

316

9.8

316

9.8

16

272

16.3

272

16.3

8

216

25.7

122

14.5

Medium Voltage
Medium Current

5 Min, 30% duty Cycle

1 Hr, 100% duty Cycle

Ohms

Volts Peak

Amps Peak

Volts Peak

Amps Peak

8

138

16.4

138

16.4

4

114

26.2

114

26.2

2

86

39.6

42

21

Low Voltage

High Current

5 Min, 30% duty Cycle

1 Hr, 100% duty Cycle

Ohms

Volts Peak

Amps Peak

Volts Peak

Amps Peak

2

58

29

58

29

1.5

52

34

52

34

1

45.4

45

45.4

45

Two 7224s in Parallel

High Voltage

Low Current

5 Min, 30% duty Cycle

1 Hr, 100% duty Cycle

Ohms

Volts Peak

Amps Peak

Volts Peak

Amps Peak

8

158

19.6

158

19.6

4

136

16.3

136

16.3

2

108

25.7

61

14.5

Medium Voltage
Medium Current

5 Min, 30% duty Cycle

1 Hr, 100% duty Cycle

Ohms

Volts Peak

Amps Peak

Volts Peak

Amps Peak

2

69

32.8

69

32.8

1

57

54.2

57

52.4

0.5

43

79.2

21

42

Low Voltage

High Current

5 Min, 30% duty Cycle

1 Hr, 100% duty Cycle

Ohms

Volts Peak

Amps Peak

Volts Peak

Amps Peak

0.5

29

58

29

58

0.375

26

68

26

68

0.25

22.7

90

22.7

90

Physical Characteristics

Chassis:
The Amplifier is designed for stand
alone or rack mounted operation. The
Chassis is black aluminum with a
powder coat finish. The unit occupies
two EIA 19-inch-wide units.

Weight:
41 lbs (18.6 kg), Shipping 51 lbs (23.2 kg)

AC Power:
Single phase, 120 VAC, 60 Hz, 20
Amp service; (220-240 VAC, 50-60
Hz, 10 Amp service model available)

Operating Temperature:
10°C to 50°C (50°F to 122°F),
Maximum Output Power de-rated
above 30°C (86°F).)

Humidity:
70% or less, non-condensing

Cooling:
Forced air cooling from front to back
through removable filters.

Airflow:
180CFM

Dimensions:
19” x 22.75” x 3.5” (48.3 cm x 57.8 cm
x 8.9 cm)

Protection

Over/Under Voltage:
± 10% from specified supply voltage
amplifier is forced to Standby

Over Current:
Breaker protection on both main power
and low voltage supplies

Over Temperature:
Separate Output transistor, heat sink,
and transformer temperature
monitoring and protection