Current over time, Frequency response – Atec AE-Techron-7224 User Manual
Page 3
7224 Datasheet
Information subject to change.
1/28/2013
Common Mode Rejection:
-58 dB with 5 V input
Display, Control, Status, I/O
Front Panel LED Displays indicate:
Ready, Standby, Fault, Over Temp,
Over Voltage, Overload
Soft Touch Switches for:
Run, Stop, Reset
Gain Control, when enabled:
Voltage gain adjustable from 20 to 0
On/Off Breaker
Back Panel Power Connection:
25 Amp IEC (with retention latch)
Signal Output:
+/Common/Sampled Common
Signal Input:
User Selectable BNC or Barrier Strip
Balanced
Communication Capabilities
Current Monitor: ± 1 V / 5 A ± 1%
Voltage Monitor: ± 1 V / 1 V ± 1%
Reporting:
System Fault, Over Temp, Over
Voltage, Over Load
Control:
Force to Standby, Reset after a fault
Multiple Unit Configuration
Series Operation:
Total Voltage (1, 2, 3, or 4-
7224’s):
150 V
pk
, 300 V
pk
, 450 V
pk
or 600 V
pk
;
Increased slew rate up to 200 V/µSec
Parallel Operation:
Total Current (1, 2, 3, or 4-
7224’s):
50 A
pk
, 100 A
pk
, 150 A
pk
or 200 A
pk
-3
-2
-1
0
1
0
30
70 110 150 190 230 270 310 350
dB
Frequency in kHz
Frequency Response
8 ohm 1
watt
10.0
15.0
20.0
25.0
0
5
10 15 20 25 30 35 40 45 50 55 60
D
C
Cu
rr
e
n
t
Time in Minutes
Current Over Time
at 13.5VDC