Ordering information – Atec California-Instruments-1001WP User Manual
Page 2
Contact California Instruments:
Toll-Free: 800-4AC-POWER
800-422-7693
FAX: 858-677-0940
Email: [email protected]
Web page: http://www.calinst.com
9689 Towne Centre Drive, San Diego, CA 92121-1964
(858) 677-9040
FAX : (858) 677-0940
© Copyright 2000, California Instruments Corp.
Specifications subject to change without notice
Printed in the USA. DS-WP 03/00
Simple, Easy to Use Limit
Testing
With preset limits at ±10% of the out-
put voltage selected, and ±3Hz of ei-
ther 50 or 60 Hz, it is extremely easy
to test products for operation over nor-
mal worst case conditions. The limit
switches feature associated LED’s to
indicate either the nominal or limit con-
dition so that the output status is im-
mediately clear.
Low Cost Of Ownership
Careful design, the use of modular con-
struction and quality components, all
contribute to provide you many years
of uninterrupted service. The modular
construction allows components or
subassemblies to be replaced quickly
to minimize downtime.
Ordering Information
Models:
1001WP 1000 VA AC Frequency
Changer.
1251WP 1250 VA AC Frequency
Changer.
Line Cord Options:
Country
Part No.
Continental Europe
PC11
Australia / New Zealand
PC12
UK / Ireland etc.
PC13
Denmark
PC14
India
PC15
Israel
PC16
Italy
PC17
Switzerland
PC19
North America*
Note 1
* One North American Line cord is in-
cluded.
Note 1:
PC21 for 1001WP
PC18 for 1251WP
Supplied with:
•
North American Line Power Cord
(PC21)
•
USA and European line output
mating connector
•
Instruction Manual
Specifications*
1001WP
1251WP
Unit
Controller
Type
Fixed
Controls
Push Buttons
Readout
Voltage
LED’s
Output
AC Power
1000
1250
VA
Voltage
Selectable
low range
100, 115
V (L-N)
high range
220, 230 , 240
V (L-N)
Accuracy
± 1 %
of setting
Limit Testing
- 10%, nominal, + 10%
Line & Load Regulation
± 2 %
Max.
Total Harmonic Distortion
≤
1 %
typical
Output Noise
low range
≤
150
mV
high range
≤
500
mV
Frequency
Selectable
50 or 60
Hz
Accuracy
± 1%
Limit Testing
-3, nominal, +3
Hz
Current
Current - Steady State
low range
9.0
11.0
A
RMS
high range
4.5
5.5
A
RMS
Peak Current
low range
29.0
33.0
A
high range
14.5
16.5
A
Protection
Output Over Current
yes
Short Circuit
yes
Over Temperature
yes
Over Voltage
yes
Input
Line Voltage
2 wire + GND
100 - 240 ±10 %
V
RMS
Input Current
< 15
< 20
A
RMS
Line Frequency
47 - 63
Hz
Holdup Time
20
ms
Power Factor
> 0.95
typical
Line Cord Input Connector
IEC320/C19
Physical
Regulatory
CE, UL, CSA
Dimensions
HxWxD
8.25 x 8.5 x 17.5
inches
HxWxD
210 x 216 x 445
mm
Weight
30 / 13.6
lbs / kg
Operating Temp.
0-40 / 32-104
°C / °F
* Specifications are warranted for an ambient temperature of 23° + 5° C and apply after a 30
minute warmup period.