beautypg.com

Ordering information – Atec California-Instruments-1001WP User Manual

Page 2

background image

Contact California Instruments:

Toll-Free: 800-4AC-POWER

800-422-7693

FAX: 858-677-0940

Email: [email protected]

Web page: http://www.calinst.com

9689 Towne Centre Drive, San Diego, CA 92121-1964

(858) 677-9040

FAX : (858) 677-0940

© Copyright 2000, California Instruments Corp.

Specifications subject to change without notice

Printed in the USA. DS-WP 03/00

Simple, Easy to Use Limit
Testing

With preset limits at ±10% of the out-
put voltage selected, and ±3Hz of ei-
ther 50 or 60 Hz, it is extremely easy
to test products for operation over nor-
mal worst case conditions. The limit
switches feature associated LED’s to
indicate either the nominal or limit con-
dition so that the output status is im-
mediately clear.

Low Cost Of Ownership

Careful design, the use of modular con-
struction and quality components, all
contribute to provide you many years
of uninterrupted service. The modular
construction allows components or
subassemblies to be replaced quickly
to minimize downtime.

Ordering Information

Models:

1001WP 1000 VA AC Frequency

Changer.

1251WP 1250 VA AC Frequency

Changer.

Line Cord Options:

Country

Part No.

Continental Europe

PC11

Australia / New Zealand

PC12

UK / Ireland etc.

PC13

Denmark

PC14

India

PC15

Israel

PC16

Italy

PC17

Switzerland

PC19

North America*

Note 1

* One North American Line cord is in-
cluded.

Note 1:

PC21 for 1001WP
PC18 for 1251WP

Supplied with:

North American Line Power Cord
(PC21)

USA and European line output
mating connector

Instruction Manual

Specifications*

1001WP

1251WP

Unit

Controller

Type

Fixed

Controls

Push Buttons

Readout

Voltage

LED’s

Output

AC Power

1000

1250

VA

Voltage
Selectable

low range

100, 115

V (L-N)

high range

220, 230 , 240

V (L-N)

Accuracy

± 1 %

of setting

Limit Testing

- 10%, nominal, + 10%

Line & Load Regulation

± 2 %

Max.

Total Harmonic Distortion

1 %

typical

Output Noise

low range

150

mV

high range

500

mV

Frequency
Selectable

50 or 60

Hz

Accuracy

± 1%

Limit Testing

-3, nominal, +3

Hz

Current
Current - Steady State

low range

9.0

11.0

A

RMS

high range

4.5

5.5

A

RMS

Peak Current

low range

29.0

33.0

A

high range

14.5

16.5

A

Protection

Output Over Current

yes

Short Circuit

yes

Over Temperature

yes

Over Voltage

yes

Input

Line Voltage

2 wire + GND

100 - 240 ±10 %

V

RMS

Input Current

< 15

< 20

A

RMS

Line Frequency

47 - 63

Hz

Holdup Time

20

ms

Power Factor

> 0.95

typical

Line Cord Input Connector

IEC320/C19

Physical

Regulatory

CE, UL, CSA

Dimensions

HxWxD

8.25 x 8.5 x 17.5

inches

HxWxD

210 x 216 x 445

mm

Weight

30 / 13.6

lbs / kg

Operating Temp.

0-40 / 32-104

°C / °F

* Specifications are warranted for an ambient temperature of 23° + 5° C and apply after a 30

minute warmup period.