INPUT SPECIFICATIONS
Input Phase
1-phase / 2-wire + Ground
Input Voltage
115/230Vac ± 15%
OUTPUT SPECIFICATIONS
Power rating
500VA
1000VA
Max Arms @
0-150V
4.2A
8.4A
Max Arms @
0-300V
2.1A
4.2A
Phase
1-phase / 2-wire + Ground
Low Range
0-150V
High Range
0-300V
Resolution
0.1V
Accuracy
± (0.5% of setting+2 counts)
Range
45 - 500Hz
Resolution
0.1Hz at 45 - 99.9Hz, 1Hz at 100 - 500Hz
Accuracy
± 0.2%
Harmonic Distortion
≤ 0.5% (Resistive Load)
Crest Factor
≥ 4 to 1
Load Regulation
± 0.5% (Resistive Load)
Protection
Over-Current, Short-Circuit, Over-Temperature
Operating Temperature
32°F - 104°F (0°C - 40°C), 80% Relative Humidity
Altitude
Below 6,500 feet
DISPLAY AND CONTROLS
4 Digital LED meters
Frequency, Voltage, Current, Power or Power Factor (simultaneously)
Memory (Standard)
3 Memories, 3 Programmable Parameters per Memory for:
Voltage, Frequency, Current Limit
Calibration
Front Panel Calibration
Auto-Voltage Adjust
Provides improved voltage regulation to within ± 0.1V
MECHANICAL SPECIFICATIONS
Power Rating
500VA
1000VA
Dimensions (In.)
H/D/W
3.5 x 16 x 17
3.5 x 22 x 17
Wieght kg/lb
22/48
37/81
©2006 ADAPTIVE POWER SYSTEMS, Ardmore, OK, U.S.A. Subject to change without notice.
PLC Remote Interface
Output
Output
Input
Input
Input Power Selector
Input Power Selector
PLC Remote Interface
Fans
801 Hailey Street Ardmore, OK 73401
Direct: 949-752-8400 • Fax: 949-756-0838
Toll Free: 1-866-517-8400
www.adaptivepower.com
TM
FC200-11/06
MODEL
FC205
FC210
Voltage
(r.m.s.)
Frequency
FC205
FC210
Fans