This series of 200 watt and 1000
watt dc power supplies take the
place of multiple power supplies
in your test system by providing
maximum power at a variety of
operating points.

Industry standard SCPI commands
and VXIPlug&Play drivers make
system integration easy. Using the
serial link, up to 16 power supplies
can be connected through one
GPIB address. These power supplies
have excellent electrical efficiency,
making them a good choice for
large systems.

Agilent Performance dc Power Supplies

speed and accuracy for test optimization

S p e c i f i c a t i o n s

(at 0

˚

to 55

˚

C unless

otherwise specified)

6030A 6031A 6032A 6033A 6035A 6038A

Power Products Catalog 2002-2003

For more detailed specifications see the product manual at

www.agilent.com/find/power

53

Save rack space by using fewer outputs

Reduce cost by using fewer power supplies

6030A, 6031A,

6032A, 6035A

6033A, 6038A

Single-Output, Autoranging:
200 W and 1000 W GPIB

Number of outputs

1

1

1

1

1

1

GPIB

Yes

Yes

Yes

Yes

Yes

Yes

Output ratings

Output Voltage

0 to 200 V

0 to 20 V

0 to 60 V

0 to 20 V

0 to 500 V

0 to 60 V

Output Current

0 to 17 A

0 to 120 A 0 to 50 A

0 to 30 A

0 to 5 A

0 to 10 A

Maximum power watts

1,200 W

1,064 W

1,200 W

242 W

1,050 W

240 W

Autoranging output

V1, I

1

200 V, 5 A

20 V, 50 A

60 V, 17.5 A 20 V, 10 A

500 V, 2 A

60 V, 3.3 A

V2, I

2

120 V, 10 A 14 V, 76 A

40 V, 30 A

14 V, 17.2 A 350 V, 3 A

40 V, 6 A

V3, I

3

60 V, 17 A

7 V, 120 A

20 V, 50 A

6.7 V, 30 A 200 V, 5 A

20 V, 10 A

Programming accuracy

Voltage 0.035% 0.035% 0.035% 0.035% 0.25%

0.035%

at 25°C ±5°C

+145 mV

+15 mV

+40 mV

+9 mV

+400 mV

+40 mV

Current 0.2%

0.25%

0.2%

0.15%

0.3%

0.09%

+25 mA

+250 mA

+85 mA

+20 mA

+63 mA

+10 mA

Ripple and noise

Voltage rms

22 mV

8 mV

8 mV

3 mV

50 mV

3 mV

20 Hz to 20 MHz

p-p

50 mV

50 mV

40 mV

30 mV

160 mV

30 mV

Current rms

15 mA

120 mA

25 mA

30 mA

50 mA

5 mA

Readback accuracy

Voltage 0.08%

0.08%

0.08%

0.07%

0.5%

0.07%

at 25°C ±5°C

+80 mV

+7 mV

+20 mV

+6 mV

+300 mV

+50 mV

Current 0.36%

0.4%

0.36%

0.3%

0.5%

0.2%

+15 mA

+100 mA

+35 mA

+25 mA

+50 mA

+11 mA

Load regulation

Voltage

0.01%+

5 mV

3 mV

5 mV

2 mV

13 mV

3 mV

Current

0.01%+

10 mA

15 mA

10 mA

9 mA

35 mA

5 mA

Line regulation

Voltage

0.01%+

5 mV

2 mV

3 mV

1 mV

13 mV

2 mV

Current

0.01%+

5 mA

25 mA

10 mA

6 mA

18 mA

2 mA

Transient response time

Time

2 ms

2 ms

2 ms

1 ms

5 ms

1 ms

10% step change

Level

150 mV

100 mV

100 mV

50 mV

200 mV 7

5 mV

V1

I1

I2

I3

Volts

P1

P2

P3

Amps

V2

V3

Autoranging Output: