General Characteristics

54810A, 54815A, 54820A and 54825A

54835A and 54845A

Altitude

Operating:

Up to 4,600 meters (15,000 ft.)

Nonoperating:

Up to 15,300 meters (50,000 ft.)

Vibration

Operating:

Random vibration 5-500 Hz, 10 minutes per axis, 0.3g(rms)

Nonoperating:

Random vibration 5-500 Hz, 10 minutes per axis, 2.41g(rms);
resonant search 5-500 Hz, swept sine, 1 octave/minute sweep
rate, (0.75g), 5 minute resonant dwell at 4 resonances per axis.

Power

Voltage: 100-240VAC, +/- 10%, Cat II, 47 to 440 Hz; Max power
dissipation: 390 W

Weight

Net: 10.6 kg (23.4 lb),

Net: 12.0 kg (26.5 lb),

Shipping: 13.6 kg (30 lb)

Shipping: 15 kg (33 lb)

Dimensions

(excluding handle)

Height: 216 mm ( 8.50 in); Width: 437 mm (17.19 in); Depth: 440 mm (17.34 in)

Safety

Meets IEC1010-1 +A2, CSA certified to C22.2 No.1010.1, Self certified to UL 3111

Notes

1

Rise time figures are calculated from tr = 0.35/bandwidth

2

54810A/15A/20A/25A: Magnification is used below 7 mV/div range. Below 7 mV/div, full scale is defined as 56 mV. 54845A: Magnification is

used below 10 mV/div range and between major attenuation settings. Full scale is defined as the major attenuator setting above an
intermediate setting. (Major settings 50

: 10 mV, 20 mV, 50 mV, 100 mV, 200 mV, 500 mV, 1 V, 1 M

: all of the above plus 2 V)

3

54810A/15A/20A/25A: The dc gain accuracy decreases 0.08% of full scale per degree C from the firmware calibration temperature.

4

For bandwidth limited signals, tr >=1.4 x sample interval

5

FFT amplitude readings are affected by input amplifier roll-off; 54810A/15A/20A/25A: (-3 dB at 500 MHz, with amplitude decreasing as

frequency increases above 500 MHz). 54845A: (-3 dB at 1.5 GHz, with amplitude decreasing as frequency increases above 1.5 GHz).

Ordering Information

www.agilent.com

Ordering Information

54810A Infiniium Oscilloscope
54815A Infiniium Oscilloscope
54820A Infiniium Oscilloscope
54825A Infiniium Oscilloscope
54835A Infiniium Oscilloscope
54845A Infiniium Oscilloscope
All of the above models include:

1 Mouse (C3751-60201), 1 Infiniium Mouse Pad (54810-85901), 1 Keyboard (E2610A),
1 User's Quick Start Guide, English language* (54810-97000), 1 Service Guide,
1 Programmer’s Guide, 1 Programmer’s Quick Reference Guide,
Information System in English, French, German, Japanese, Korean and Chinese (for Taiwan),
2 1160A 10:1 10 M

passive probes (54810A, 54820A), 4 1160A 10:1 10 M

passive probes (54815A, 54825A), 4 1161A 10:1 10 M

passive probes (54635A, 54845A),

1 Accessory Pouch (54810-68701), 1 US power cord, Three-year warranty

* Other languages also available

Options

090 Delete standard probes

2 1160A probes for the 54810A/20A
4 1160A probes for the 54815A/25A
4 1161A probes for the 54835/45A

001* Additional standard probes

2 1160A probes for the 54810A/15A/20A/25A
2 1161A probes for the 54835/45A

002* Add 1 1162A 1:1 passive probe
003* Add 1 1163A 10:1 500

, low C passive probe

006* Add 1 1152A 2.5 GHz, .6 pF active probe (for 54835/45A)
008* Add 1 1153A 200 MHz differential probe
009 Add 1 1154A 500 MHz differential probe
010 Add 1 1159A 1 GHz differential probe
015 Extended (runt) triggering (standard on 54835A/54845A)
100* Communications Mask Test Kit

includes mask library disk and set of termination adapters

200 VoiceControl option
1BP Mil Std 45662A and ANSI/NCSL Z-540 calibration with test data
1CL* Add 1 Keyboard (E2610A)
1CM*Add 1 Rackmount kit (E2609A)
UL5* Add 1 Touchpad pointing device (E2612A)
UL6* Add 1 Clip-on track ball pointing device (E2611A)
W50 Five-year, customer-return, repair coverage (additional 2 years)
* Multiple options can be ordered

For more information about Agilent
Technologies test and measurement
products, applications, services, and for a
current sales office listing, visit our web
site:
http://www.agilent.com/find/infiniium
You can also contact one of the following
centers and ask for a test and
measurement sales representative.

United States:
Agilent Technologies
Test and Measurement Call Center
P.O. Box 4026
Englewood, CO 80155-4026
(tel) 1 800 452 4844

Canada:
Agilent Technologies Canada Inc.
5150 Spectrum Way
Mississauga, Ontario
L4W 5G1
(tel) 1 877 894 4414

Europe:
Agilent Technologies
Test & Measurement
European Marketing Organisation
P.O. Box 999
1180 AZ Amstelveen
The Netherlands
(tel) (31 20) 547 9999

Japan:
Agilent Technologies Japan Ltd.
Measurement Assistance Center
9-1, Takakura-Cho, Hachioji-Shi,
Tokyo 192-8510, Japan
(tel) (81) 426 56 7832
(fax) (81) 426 56 7840

Latin America:
Agilent Technologies
Latin American Region Headquarters
5200 Blue Lagoon Drive, Suite #950
Miami, Florida 33126 U.S.A.
(tel) (305) 267 4245
(fax) (305) 267 4286

Australia/New Zealand:
Agilent Technologies Australia Pty Ltd
347 Burwood Highway
Forest Hill, Victoria 3131
(tel) 1-800 629 485 (Australia)
(fax) (61 3) 9272 0749
(tel) 0 800 738 378 (New Zealand)
(fax) (64 4) 802 6881

Asia Pacific:
Agilent Technologies
19/F, Cityplaza One, 1111 King’s Road,
Taikoo Shing, Hong Kong, SAR
(tel) (852) 2599 7889
(fax) (852) 2506 9233

Technical data is subject to change
Windows and MS-DOS are registered
trademarks of Microsoft Corporation.
© Agilent Technologies 2000
Printed in the U.S.A. 2/00
5968-8496EN

This manual is related to the following products: