Power supply

Temperature

control system
Operation temperature

Heat exhaust

Noise

Temperature

range *3

Temperature

heat-up rate
Temperature

pull-down rate
Lowest attainable

temperature
Exterior material
Interior material
Insulation
Door
Instrumentation panel

Heater

Refrigeration system
Cooler
Refrigerator
Refrigerator capacity
Refrigerant

Fittings

Inside dimensions

(W×H×D mm/ in)
Outside dimensions

(W×H×D mm/ in)

Capacity (L)
Weight (kg)

Temperature

fluctuation *3

Temperature

uniformity *3

Dimensions

Construction

Performance

*2

100V

115V

Maximum current *1 200V

220V
230V

100V AC 1φ50/60Hz, 115V AC 1φ60Hz

220V AC 1φ50/60Hz, 230V AC 1φ50Hz

230V AC 1φ50Hz (Compliance with CE Marking)

Balanced Temperature control system (BTC system)

5 to +35℃ (+41 to +95

F)

Painted steel

18-8 Cr-Ni stainless steel plate (SUS 304)

Rigid polyurethane foam, Glass wool

one-panel door (right handle, left hinge)

Temperature indicator controller, Overheat protector, Overcool protector

Plate fin cooler

Compressor: Air-cooled hermetically sealed compressor, Condenser: Air-cooled condenser, Expansion mechanism: Capillary tube

Connecting terminal for temp recorder terminal, Specimen power supply control terminal

External alarm terminal, External output terminal, Cable ports, Power cord/ plug, Drain pipe

Mechanical single-stage refrigerator system

400W

R404A

400W+400W

R404A, R23

Mechanical cascade condenser refrigeration system

300Ч300Ч250/ 11.8Ч11.8Ч9.8

(excluding protrusions)

400Ч400Ч400/ 15.7Ч15.7Ч15.7

(excluding protrusions)

22.5

64

115

95

66 (71 for 115, 220, 230V)

440Ч560Ч695/ 17.3Ч22.0Ч27.4

(730/ 28.7D when including protrusions)

440Ч560Ч785/ 17.3Ч22.0Ч30.9

(825/ 32.5 when including protrusions)

540Ч660Ч890/ 21.3Ч26.0Ч35.0

(930/ 36.6D when including protrusions)

Nichrome-stripped wire heater

     

400W                         600W

At 1m from front of chamber, 1.2m from floor (depending on environment)

10.0A

13.5A

18.0A

9.5A

13.0A

10.0A

6.0A

7.5A

9.0A

5.5A

7.0A

60 to +150℃

(−76 to +302

F)

40 to +150℃

(−40 to +302

F)

60 to +150℃

(−76 to +302

F)

40 to +150℃

(−40 to +302

F)

20 to +150℃

(−4 to +302

F)

60 to +150℃

within 70 min

40 to +150℃

within 70 min

60 to +150℃

within 80 min

40 to +150℃

within 60 min

20 to +150℃

within 55 min

20 to −60℃

within 70 min

20 to −40℃

within 60 min

20 to −60℃

within 90 min

20 to −40℃

within 50 min

20 to −20℃

within 20 min

60℃ (−76

F)

40℃ (−40

F)

60℃ (−76

F)

40℃ (−40

F)

20℃ (−4

F)

±

0.3℃ (−60 to +100℃)

[±

0.54

。F (−76 to +212。F)]

±

0.5℃ (+100.1 to +150℃)

[±

0.9

。F (+212.1 to +302。F)]

±

0.3℃ (−40 to +100℃)

[±

0.54

。F (−40 to +212。F)]

±

0.5℃ (+100.1 to +150℃)

[±

0.9

。F (+212.1 to +302。F)]

±

0.3℃ (−60 to +100℃)

[±

0.54

。F (−76 to +212。F)]

±

0.5℃ (+100.1 to +150℃)

[±

0.9

。F (+212.1 to +302。F)]

±

0.3℃ (−40 to +100℃)

[±

0.54

。F (−40 to +212。F)]

±

0.5℃ (+100.1 to +150℃)

[±

0.9

。F (+212.1 to +302。F)]

±

0.3℃ (−20 to +100℃)

[±

0.54

。F (−4 to +212。F)]

±

0.5℃ (+100.1 to +150℃)

[±

0.9

。F (+212.1 to +302。F)]

±

0.5℃ (−60 to +100℃)

[±

0.9

。F (−76 to +212。F)]

±

0.8℃ (+100.1 to +150℃)

[±

1.44

。F (+212.1 to +302。F)]

±

0.5℃ (−40 to +100℃)

[±

0.9

。F (−40 to +212。F)]

±

0.8℃ (+100.1 to +150℃)

[±

1.44

。F (+212.1 to +302。F)]

±

0.5℃ (−60 to +100℃)

[±

0.9

。F (−76 to +212。F)]

±

0.8℃ (+100.1 to +150℃)

[±

1.44

。F (+212.1 to +302。F)]

±

0.5℃ (−40 to +100℃)

[±

0.9

。F (−40 to +212。F)]

±

0.8℃ (+100.1 to +150℃)

[±

1.44

。F (+212.1 to +302。F)]

±

0.5℃ (−20 to +100℃)

[±

0.9

。F (−4 to +212。F)]

±

0.8℃ (+100.1 to +150℃)

[±

1.44

。F (+212.1 to +302。F)]

8.5A

55dB

59dB

61dB

3500kJ/h

4000kJ/h

5040kJ/h

100V AC 1φ50/60Hz, 200V AC 1φ50/60Hz

220V AC 1φ50/60Hz, 230V AC 1φ50Hz

230V AC 1φ50Hz (Compliance with CE Marking)

Model

SU-221

SU-241

SU-261

SU-641

SU-661

*1 At +23℃ ambient temperature, value at stable voltage application. For SU-641/ 661, make sure to check the capability of your power equipment in advance.
*2 At +23℃ ambient temperature, value at stable voltage application with no specimen. Lowest attainable temperature value at ambient of up to +30℃.
*3 In accordance with Standard for Performance of Humidity Chamber (JTM-K01-1998) of standard of Japan Testing Machinery Association.

SU