Atec California-Instruments_MX Series User Manual
Page 7
858.458.0223
223
15–135 kVA
MX Series II : Specifications
AC Input
Voltage
Must be specified at time of order. All inputs are L-L, 3ø, 3 wire + Gnd. 208 ± 10% VAC, 230 ± 10% VAC, 400 ± 10% VAC,
480 ± 10% VAC
Input Line Current (per phase)
Current (MX15):
Current (MX30/45):
V L-L
208
230
400
480
V L-L
208
230
400
480
St State 58.3 ARMS 52.3 ARMS 30 ARMS 25 ARMS
St State 116/175 ARMS 105/157 ARMS 60/90 ARMS 50/75 ARMS
Distortion: < 8 % at full power < 20 % below 35 % of power
Line Frequency
47 - 63 Hz
Efficiency
85 % typical
Power Factor
0.95 typical
AC Service
Inputs/Outputs
MX30/MX45: Front access, cables routed through rear panel, exit in back. MX15: Rear Access
Regulatory
IEC61010, EN50081-2, EN50082-2, CE EMC and Safety Mark requirements
EMI
CISPR 11, Group1 , Class A
Connectors
AC Input & Output terminal block behind front cover, IEEE-488 (GPIB) connector (rear panel), 9 pin D-Shell RS232C connector*, (rear
panel), Remote voltage sense terminal block (rear panel), System Interface Connector, DB-37 (rear panel). *RS232 DB9 to DB9 cable
supplied
Physical Dimensions
MX30/MX45 Dimensions
Height: 50.0” (1270 mm), Width: 28.75” (731 mm), Depth: 34.5” (876 mm)
MX30/MX45 Weight
Chassis: Net: 1150 lbs / 522 Kg, Shipping: 1231 lbs / 560 Kg, Amp Module: Net: 63 lbs / 29 Kg
MX15 Dimensions
Height: 31.75” (806 mm), Width: 24.0” (610 mm), Depth: 28.0” (711 mm)
MX15 Weight
Chassis: Net: 600 lbs / 272 Kg, Shipping: 681 lbs / 309 Kg, Amp Module: Net: 63 lbs / 29 Kg
Chassis
MX30/MX45: Casters and forklift openings. MX15: Casters
Vibration and Shock
Designed to meet NSTA project 1A transportation levels. Units are shipped in wooden crate with forklift slots
Air Intake/Exhaust
Forced air cooling, front air intake, rear exhaust
Operating Humidity
0 to 95 % RAH, non condensing
Temperature
Operating: 0 to 40° C (30° C max in CP mode), Storage:
-20 to +85° C
Standard controller versions with single voltage range
Model
AC Output Power
Phase Outputs
AC/DC Voltage Range
Controller
MX15-1
15 kVA
1
150/200 or 300/400
Standard
MX30-1
30 kVA
1
150/200 or 300/400
Standard
MX30-3
30 kVA
3
150/200 or 300/400
Standard
MX45-1
45 kVA
1
150/200 or 300/400
Standard
MX45-3
45 kVA
3
150/200 or 300/400
Standard
MX90-3
90 kVA
3
150/200 or 300/400
Standard
MX135-3
135 kVA
3
150/200 or 300/400
Standard
Programmable controller versions with dual voltage ranges
Model
AC Output Power
Phase Outputs
AC/DC Voltage Range
Controller
MX15-1Pi
15kVA
1
150/200 & 300/400
Programmable
MX30-3Pi
30 kVA
1 & 3
150/200 & 300/400
Programmable
MX45-3Pi
45 kVA
1 & 3
150/200 & 300/400
Programmable
MX90-3Pi
90 kVA
3
150/200 & 300/400
Programmable
MX135-3Pi
135 kVA
3
150/200 & 300/400
Programmable
Pi models include IEEE-488, RS232C & USB interfaces, Advanced measurements, arbitrary waveform generation. Phase mode switching on MX-30/45-3Pi.
Programmable controller versions with dual voltage ranges
Model
AC Output Power
Phase Outputs
AC/DC Voltage Range
Controller
MX90-3Pi-MB
90 kVA
3
150/200 & 300/400
Dual MX45-3Pi
MX135-3Pi-MB
135 kVA
3
150/200 & 300/400
Triple MX-45-3Pi
Reconfigurable systems can be separated into stand-alone MX45-3Pi models or combined for higher power levels.