Mx series ii : specifications – Atec California-Instruments_MX Series User Manual
Page 6
www.ProgrammablePower.com
222
MX Series II : Specifications
Measurement
Measurements - Standard
(AC Measurements)
Parameter
Frequency
RMS
Voltage
RMS
Current
Peak
Current
Crest
Factor
Real
Power
Apparent
Power
Power
Factor
Phase
DC
Voltage
DC
Current
Power
Range
16-100 Hz
100-820 Hz
0-400 V
0-160 A
0-400 A
0.00-6.00 0-15 kW
0-15 kVA 0.00-1.00 0.0-360.0 0-400 V
0-160 A Power
Accuracy*
(±)
0.01% +
0.01 Hz
0.05 V +
0.02%
0.1 V +
0.02%
0.15 A +
.02%
0.3 A +
0.02%
0.15 A +
0.02%
0.3 A +
0.02%
0.05
0.05
30 W +
0.1%
60 W +
0.1%
30 VA +
0.1%
60 VA +
0.1%
0.01
0.02
2.0°
3.0°
0.5 V
0.5 A
0.15 kW
Resolution* 0.01 Hz /
0.1 Hz
10 mV
10 mA
10 mA
0.01
10 W
10 VA
0.01
0.1°
10 mV
10 mA
10 W
* Measurement system bandwidth = DC to 6.7 kHz. Accuracy specifications are valid above 100 counts. Current and Power Accuracy and Range specifications are
times three for MX90, MX135 or MX30/45-3Pi in single phase mode. PF accuracy applies for PF > 0.5 and VA > 50 % of range
Measurements - Harmonics
(Pi controller only)
Parameter
Frequency Fundamental Harmonics
Phase
Voltage
Current
Range
16.00-1000.0 Hz / 32.00 Hz - 16 kHz
0.0 - 360.0° Fundamental Harmonics 2-50
Fundamental Harmonics 2-50
Accuracy* (±)
0.03% + 0.03 Hz / 0.01 Hz
2° typ.
750 mV 0.3% + 750 mV+0.3% /1 kHz
0.5 A / 0.3% + 150 mA +0.3% /1 kHz
Resolution
0.01 Hz
0.5°
10 mV / 10 mV
100 mA / 100 mA
* Accuracy specifications are valid above 100 counts. Accuracy specifications are for three phase mode. Harmonics frequency range for MX30/45-3Pi in single phase
mode is 32 Hz - 48 kHz
DC Mode Output
Power
Maximum DC power at full scale of DC voltage range. MX15-1Pi: (10 kW), MX30-3Pi: (6.5 kW per output, 3 outputs. 20 kW in
1 channel mode), MX45-3Pi: (10 kW per output, 3 outputs. 30 kW in 1 channel mode)
Voltage Ranges
Range: Low (0 - 200 V), High (0 - 400 V)
Output Accuracy
± 1 Vdc
Load Regulation
< 0.25 % FS
Line Regulation
< 0.1% FS or 10 % line change
Ripple
< 2 Vrms Lo Range, < 3 Vrms Hi Range
Max DC Current @ FSV per output
Model MX15-1 MX15-1Pi MX30-1 MX30-3 MX30-3Pi / 1Phs MX45-1 MX45-3 MX45-3Pi / 1Phs MX90-3/Pi MX135-3/Pi
V Low 50
50
200
66.7
33.3 / 100
150
50
50 / 150
100
150
V High 25
25
100
16.6
16.6 / 50
75
25
25 / 75
50
75
Note: Constant power mode provides increased current at reduced voltage. See chart on previous page
Current Limit
Programmable from 0 A to max. current for selected range
AC+DC Mode Output
Output (Pi) Power
Maximum current and power in AC+DC mode is same as DC mode
Protection
Over Load
Constant Current or Constant Voltage mode
Over Temperature
Automatic shutdown
Storage
Non Volatile Mem. storage
16 instrument setups, 200 user defined waveforms [Pi only]
Waveforms
Waveform Types
Std: Sine, Pi: Sine, Square, Clipped sine, User defined
User defined waveform storage (Pi version)
Four groups of 50 user defined arbitrary waveforms of 1024 points for a total of 200. One group can be active at a time
System Interface
Inputs
Remote shutdown, External Sync, Clock/Lock (option on Pi)
Outputs
Function Strobe / Trigger out, Clock/Lock (option on Pi)
Remote Control (Pi standard with -P option)
IEEE-488 Interface
IEEE-488 (GPIB) talker listener. Subset: AH1, C0, DC1, DT1, L3, PP0, RL2, SH1, SR1, T6, IEEE-488.2 SCPI Syntax
RS232C Interface
9 pin D-shell connector (Supplied with RS232C cable)
LAN
Ethernet Interface: 10BaseT, 100BaseT, RJ45
USB
Version: USB 1.1; Speed: 460 Kb/s maximum
Output Relay
Push button controlled or bus controlled output relay
Output impedance
Programmable Z available on MX30-3Pi and MX45-3Pi in 3 phase mode only. Specifications apply at 50 Hz fundamental.
Resistive: 1 - 200 mOhm, Inductive: 15 - 200 uH