beautypg.com

Atec California-Instruments_MX Series User Manual

Page 5

background image

858.458.0223

[email protected]

221

MX Series II : Specifications

15–135 kVA

Operating Modes

Standard

AC or DC

Pi Version

AC, DC and AC+DC

AC Mode Output

Frequency

Range: 16.00-819.0 Hz, -LF Option: 16.00-500.0 Hz, -HF Option: 16.00-1000 Hz (supplemental specifications apply above
819 Hz). Resolution: 0.01 Hz: 16.00 - 81.91 Hz, 0.1 Hz: 82.0 Hz - 819.1 Hz, 1 Hz: 820-1000 Hz

Phase Outputs

MX15-1/15-1Pi: 1, MX30/45-3Pi: 1 or 3 switchable, Neutral: Floating, Coupling: DC (except for -HV option)

Total Power

MX15-1/1Pi: 15 kVA, MX30-1/3: 30 kVA, MX45-1/3: 45 kVA, MX90: 90 kVA, MX135: 135 kVA

Load Power Factor

0 to unity at full output current

AC Mode Voltage

Voltage Ranges

Range

V Low

V High

Load Regulation

< 0.25 % FS DC to 100 Hz, < 0.5 % FS 100 Hz to 819 Hz

AC

0-150 V

0-300 V

Line Regulation

< 0.1% FS for 10 % line change

AC+DC

0-150 V

0-300 V

External Sense

Voltage drop compensation (5% Full Scale)

Harmonic Distortion (Linear)

Less than 0.5% from 16 - 66 Hz, Less than 1% from 66 - 500 Hz, Less than 1.25% above 500 Hz

DC Offset

< 20 mV

Load Regulation

0.25% FS @ DC - 100 Hz, 0.5% FS > 100 Hz

External Amplitude Modulation

Depth: 0 - 10 %, Frequency: DC - 2 KHz

Voltage slew rate

200 µs for 10% to 90% of full scale change into resistive load

AC Mode Current

Steady State AC Current @ FS V

Model MX15-1 MX15-1Pi MX30-1 MX30-3 MX30-3Pi / 1Pi MX45-1 MX45-3 MX45-3Pi / 1Pi MX90-3/Pi MX135-3/Pi

V Low 100

100

200

66.6/ш

66.6/ш / 200

300

100/ш

100/ш / 300

200/ш

300/ш

V High 50

50

100

33.3/ш

33.3/ш / 100

150

50/ш

50/ш / 150

100/ш

150/ш

Note: Constant power mode provides increased current at reduced voltage. See chart below

Peak Repetitive AC Current

Up to 3.6 x rms current at full scale voltage

Programming Accuracy

Voltage (rms): ± 0.3 Vrms, Frequency: ± 0.01 % of programmed value, Current Limit: - 0 % to + 5 % of programmed value + 1A, Phase:
< 0.5° + 0.2°/ 100 Hz with balanced load

Programming Resolution

Voltage (rms): 100 mV, Frequency: 0.01 Hz from 16 - 81.91 Hz, 0.1 Hz from 82.0 - 819 Hz, Current Limit: 0.1 A, 3 phase mode,
1.0 A, 1 phase mode, Phase: 0.1°

Constant Power AC Mode - Available Max. AC Current

Current

(RMS)

Voltage (RMS)

Full

Power

125%

100%

20%

50%

10%

80%

50%

100%

Note: Specifications are subject to change without notice. Specifications are warranted over an ambient temperature range of 25°± 5° C. Unless otherwise noted, specifications are per phase

for a sinewave with a resistive load and apply after a 30 minute warm-up period. For three phase configurations, all specifications are for L-N. Phase angle specifications are valid under
balanced load conditions only.

© 2009 AMETEK Programmable Power All rights reserved. AMETEK Programmable Power is the trademark of AMETEK Inc., registered in the U.S. and other countries. Elgar, Sorensen,

California Instruments, and Power Ten are trademarks of AMETEK Inc., registered in the U.S.