Micropulse module,

Pulses based on SAE J1455

SAE J1455

Mutual Pulse as per SAE J1455

Rise time tr (10% - 90%)

1µs +20%

Pulse duration td at

τ

15µs

± 20%

Internal resistor

50

Ω ± 10%

Inductive Pulse as per SAE J 1455

Rise time tr (10 - 90%)

1µs

± 20%

Pulse duration td at

τ

1,000µs

± 20%

Internal resistor

20

Ω ± 10%

Options

CA ISO

Micropulse/Load Dump pulse verification kit

The SmartRack

Sophisticated Housing for Sophisticated Instruments

General data

General data

Dimensions, weight
For models 50A

19“ / 3HU, approx. 20kg

For models 100A

19“ / 6HU, approx. 30kg

For models 150A and 200A

19“ / 9HU, approx. 35kg

Supply voltage

115/230V +10/-15%

Fuses

2 x T 2AT (230V) or 2 x T 4AT (115V)

Options

Rack

For system integration; includes GPIB
bus, pulse bus, ground reference plane,
security switch and power contact.

ISMISO

Software to control the test, including
standard library, test report facility and
data conversion generator.

UCS 200M 200A model

The best place to put your generators is in the SmartRack. A wired, "intel-
ligent" rack, the SmartRack not only holds, but also interconnects and
controls equipment. Slide your generators into the SmartRack and you
can run entire test routines from your PC with no plugging or unplugging,
no stops or starts.

Select from a comprehensive directory of the most recent pre-
programmed international and manufacturer standards – including custom
pulse waveforms – and the SmartRack does the rest. You can modify test
parameters and even create your own tests.

Just how easy is testing with the SmartRack? Consider this:
• The Device Under Test (DUT) voltage has one easy connection at the
UCS 200M coupling unit
• No need to keep plugging and unplugging DUTs
• The test rack has a ground reference plane that matches with the test

table specified in ISO 7637-2:2004

• ISM ISO (SmartRack) software controls the entire test process.
It generates test reports as well
• Tests can be initiated from front panels as well as from a PC

Technical data subject to change without notice.