beautypg.com

Micropulses – Atec EM-Test-UCS200N User Manual

Page 4

background image

KARTA KATALOGOWA > UCS 200N-series > 20120209

PARAMETRY TECHNICZNE

MICROPULSES

MICROPULSE MODULE FOR TEST PULSES 1, 2A AND 6

As per ISO 7637-2:2011

Test voltage

U = 20V - 600V ± 10%
(peak voltage and polarity as per
selected standard)

Repetition rate

0.2s - 99.0s

ISO PULSE 1 (12V)

Rise time

1us +0%/-50% (10% - 90%)

Pulse duration

2ms ± 10% (10% - 10%)

Int. resistor

10ohm ± 10%

ISO PULSE 1 (24V)

Rise time

3us +0%/-50% (10% - 90%)

Pulse duration

1ms ± 10% (10% - 10%)

Int. resistor

50ohm ± 10%

ISO PULSE 2 (12V/24V)

Rise time

1us +0%/-50% (10% - 90%)

Pulse duration

50us ± 10% (10% - 10%)

Int. resistor

2ohm ± 10%

ISO PULSE 6 (12V) AS PER ISO 7637-1:1990

Rise time

60us +0%/-50% (10% - 90%)

Pulse duration

300us ± 10% (10% - 10%)

Int. resistor

30ohm ± 10%

AS PER ISO 7637-2 THE FOLLOWING STANDARDS CAN BE
COVERED

SAE J1113

GM 3097

BMW

Volkswagen

PSA

Chrysler PF 9326

DC 10614

Renault

FIAT

Mitsubishi

Honda

Ford ES-XW7T

MICROPULSES

TRIGGER

Automatic

Automatic release of the pulses

Manual

Manual release of a single pulse

External

External release of a single pulse

Battery switch

Off time, selectable; 0 - 10,000ms

OUTPUT

DUT supply +/-

Central DUT output

Coupling

To the battery +line

Decoupling

Via diode and battery supply switch

TEST ROUTINES

Quick Start

Immediate start; easy to use and fast

User Test routines

1. Custom made test routines
2. Change voltage after n pulses

Standard Test
routines

As per ISO 7637, SAE J1113, JASO
and manufacturer specifications

Service

Service, setup, self test

www.emtest.com

© EM TEST > STRONA 4/7