Major specifications – Atec Agilent-4395A-1D6-4396B User Manual
Page 5
5
Network analyzer specification
Spectrum analyzer specification
Impedance analyzer specification
2
Frequency range
10 Hz to 500 MHz
1
Frequency range
10 Hz to 500 MHz
Frequency range
100 kHz to 500 MHz
Frequency resolution
1 mHz
Noise sidebands
< –104 dBc/Hz
Meas. parameter
|Z|,
θz, R, X, |Y|,
typical at 10 kHz
θy, G, B, Cs, Cp, Ls,
offset
Lp, Rp, Rs, X, D, Q,
I
ΓI, Γx ,Γy
Output power range
–50 to15 dBm
Resolution bandwidth
1 Hz to 1 MHz in
Z accuracy
±3% (typical,
1-3-10 steps
basic accuracy)
Dynamic range
115 dB @ 10 Hz IFBW Dynamic range
> 100 dB third-order Source level
–56 dBm to
free dynamic range
+9 dBm (at DUT)
Dynamic accuracy
±0.05 dB/0.3 deg.
Level accuracy
±0.8 dB @ 50 MHz
DC bias
±40 V (20 mA (max))
Calibration
Full two-port
Sensitivity
–145 dBm/Hz
(Option 4395A-001
@ freq. = 10 MHz
DC source or external
DC source is required.)
Compensation
OPEN/SHORT/LOAD
port extension
Standard features: Instrument BASIC, GPIB port, 3.5" floppy disk drive, direct print, RAM disk, VGA monitor output.
Optional features: Impedance measurement (Option 4395A-010), time-gated spectrum analysis (Option 4395A-1D6), high-stability frequency
reference (Option 4395A-1D5), 50
Ω to 75 Ω spectrum input impedance conversion (Option 4395A-1D7), DC source
(±40 V, 100 mA (ALC)) (Option 4395A-001).
1. 100 kHz to 500 MHz if using the Agilent 87511A/B S-parameter test set.
2. With Option 4395A-010 and the Agilent 43961A RF impedance test kit
Network analyzer specification
Spectrum analyzer specification
Impedance analyzer specification
2
Frequency range
100 kHz to 1.8 GHz
1
Frequency range
2 Hz to 1.8 GHz
Frequency range
100 kHz to 1.8 GHz
Frequency resolution
1 mHz
Noise sidebands
< –113 dBc/Hz
Meas. parameter
|Z|,
θz, R, X, |Y|,
typical at 10 kHz
θy, G, B, Cs, Cp,
offset
Ls, Lp, Rp, Rs, X,
D, Q, I
Γ I, Γx,Γy
Output power range
–60 to 20 dBm
Resolution bandwidth
1 Hz to 3 MHz in
Meas. range
2
Ω to 5 kΩ
1-3-10 steps
Dynamic range
> 120 dB @ 10 Hz
Dynamic range
> 100 dB third-order Z accuracy
±3% (typical,
IFBW
dynamic range
basic accuracy)
Dynamic accuracy
±0.05 dB/0.3 deg.
Overall level accuracy
< ±1.0 dB
Source level
–66 dBm to
Calibration
Full two-port
Sensitivity
< –147 dBm/Hz
+14 dBm (at DUT)
@ freq. = 1 GHz
DC bias
±40 V (20 mA (max))
(External DC bias
source is required.)
Compensation
OPEN/SHORT/LOAD
port extension
Standard features: Instrument BASIC, GPIB port, 3.5" floppy disk drive, direct print, RAM disk, VGA monitor output.
Optional features: Impedance measurement (Option 4396B-010), time-gated spectrum analysis (Option 4396B-1D6), high-stability frequency
reference (Option 4396B-1D5), 50
Ω to 75 Ω spectrum input impedance conversion (Option 4396B-1D7).
1. 300 kHz to 1.8 GHz if using the Agilent 85046A/B S-parameter test set.
2. With Option 4396B-010 and the Agilent 43961A RF impedance test kit.
Major Specifications
Agilent 4395A
Agilent 4396B
100 kHz to 500 MHz