Atec Agilent-66312A User Manual
Page 4
Specifications - A
51
Table A-2. Supplemental Characteristics (continued)
Parameter
Agilent 66312A
Agilent 6611C -
6614C
Dynamic Measurement
Accuracy
Instantaneous Voltage:
Instantaneous Current:
0.03% + 5 mV
0.6% + 1 mA
1
not applicable
Dynamic Measurement
System
Buffer Length:
Sampling Rate Range:
4096 points
15.6
µ
s
−
31,200s
not applicable
Measurement Time
(voltage or current)
50 ms average
(includes the default time of 30 ms
2
for acquiring
data, and a 20 ms data processing overhead)
Command Processing
Time
4 ms average
(for output to begin to change
following receipt of digital data)
Remote Sense Capability
Up to 2 V can be dropped across each load lead.
(add 2 mV to the voltage load regulation
specification for each 1 V change in the positive
output lead due to load current change.)
Savable Instrument States
(applies only in SCPI mode)
4 (in locations 0 to 3)
RS-232 Interface
Capabilities
Baud rates:
Data formats:
Language:
300 600 1200 2400 4800 9600
7 bits even or odd parity; 8 bits without parity
SCPI or COMPatibility
3
GPIB Interface
Capabilities
Language:
Interface:
SCPI or COMPatibility
3
AH1, C0, DC1, DT1, E1, L4, PP0, RL1, SH1,
SR1, T6
INH/FLT Characteristics
Maximum ratings:
FLT Terminals:
INH Terminals:
16.5 Vdc between terminals 1 and 2; 3 and 4; and
from terminals 1 or 2 to chassis ground
Low-level output current = 1.25 mA max.
Low-level output voltage = 0.5 V max.
Low-level input voltage = 0.8 V max.
High-level input voltage = 2 V min.
Low-level input current = 1 mA
Pulse width = 100
µ
s min.
Time delay = 4 ms typical
Digital I/O Characteristics
Maximum ratings:
Digital OUT Port 0,1,2
(open collector)
same as INH/FLT Characteristics
Output leakage @ 16V = 0.1 mA (ports 0,1)
= 12.5 mA (port 2)
Output leakage @ 5V = 0.1 mA (ports 0,1)
= 0.25 mA (port 2)
Low-level output sink current @ 0.5 V = 4 mA
Low-level output sink current @ 1 V = 50 mA
1
For full scale current changes with a risetime of 20
µ
s, an additional 0.5% error exists in the first data point in the buffer after the change. The
error percentage increases proportionally with the decrease in risetime.
2
This time may be reduced by changing the default conditions of 2048 data points, however, measurement accuracy will be reduced.
3
COMPatibility language is used to program the Agilent 663xA Series power supplies.