Versions and accessories – Atec Aeroflex-3920B User Manual
Page 22

GRAPHICAL DIsPLAYs
TETRA CHANNEL PLANs AND sIGNALING
VERSiOnS AnD ACCESSORiES
When ordering please quote the full ordering number information.
Ordering
number
Description
91164
3920B Analog and Digital Radio Test Platform
Accessories Standard with 3920B
Front/Rear Cover
2 X Adapter (BNC-F to TNC-M)
Adapter (N-M to BNC-F)
3900 Series Operation Manual (CD-ROM)
Antenna (BNC) (450 MHz)
Antenna (BNC) (800 MHz)
Antenna (BNC) (150 MHz)
3900 Series Getting Started Manual
Warranty Packet, 2 Year
2 X Fuse, 3 Amp, 250V
Power Cord (configuration for use in the UK)
Power Cord (configuration for use in North America)
Power Cord (configuration for use in Continental Europe)
3-Wire (grounded) power cord
Options
Description
83352
390XOPT051 Site Monitoring Application
83353
390XOPT054 IQ Gen Modulation (for IQ Creator
waveforms)
83354
390XOPT055 Audio Analyzer
83390
392XOPT058 2.7 GHz Frequency Range
Extension Option
83355
390XOPT059 Auto-Test II Analog
83356
390XOPT060 Harmonics & Spurious
Measurements
83357
390XOPT061 Tracking Generator
83358
390XOPT064 Analog Duplex Power Between
Markers
92573
390XOPT067 POCSAG
84410
390XOPT090 Chinese GUI
22
POWER PROFILE DIsPLAY
Display of power versus time for a
complete burst or ramp up/ramp
down intervals measured at the
symbol points and displayed relative
to a TETRA mask (TETRA limits or
user defined) with pass/fail
indication. Measured through a
TETRA filter referenced (0 dB) to
average power.
Dynamic Range
70 dB
Vertical Scale
20 dB/div or 0.1 dB/div in 1, 2, 5
steps
Accuracy
±1.0 dB (±0.6 dB typical) at
symbol points for levels greater
than -10 dB
CONsTELLATION DIsPLAY
Polar display of amplitude versus
phase at the symbol point measured
over all symbols (SN0 ~ SN max)
through a TETRA filter. Also available
as a rotated constellation display
where all symbol point
values are mapped to a single
constellation point.
PHAsE TRAJECTORY
DIsPLAY
Polar display of amplitude versus
phase continuously measured over
the duration (SN0 ~ SN max)
through a TETRA filter.
VECTOR ANALYsIs
DIsPLAYs
Vector error (%), magnitude error
(%) and phase error (degrees)
measured at symbol points (SN0 ~
SN max) through a TETRA filter.
Vertical scaling
Vector error 0.1%/div to 20%/div in
1, 2, 5 steps
Phase error ±0.1°/div to ±20°/div
in 1, 2, 5 steps
Magnitude error ±1.0 %/div to
±20%/div in 1, 2, 5 steps
Channel Plans
TETRA 380-400 (0 Hz or 12.5 kHz offset)
TETRA 410-430 (0 Hz, -6.25 kHz or
12.5 kHz offset)
TETRA 450-470 (0 Hz or 12.5 kHz offset)
TETRA 805-870 (0 Hz or 12.5 kHz offset)
TETRA 870-921 (0 Hz or 12.5 kHz offset)
No plan and user defined
system Identity
Mobile Country Code, MCC
Mobile Network Code, MNC
Base Color Code, BCC
Location Area Code, LA
FREQUENCY ERROR
Range
±500.0 Hz
Resolution
0.1 Hz
Accuracy
±15 Hz +frequency standard
accuracy
BER Testing (TETRA
MS T1 mode)
BER, MER and PUEM
BER Testing (TETRA
MS mode)
BER, RBER and MER
BER Testing (TETRA
BS T1 mode)
BER, MER and PUEM
signaling
Functions
Mobile parameter control for SSI, GSSI, power
class, receiver class
Registration, test mode registration and
de-registration
Private (individual) call, group call, phone call,
emergency call, user defined call (mobile
terminated)
Call timer and trunking type selection
Cell-re-selection (requires two test sets and a
power splitter)
Short data service
Status message and SDS types 1 to 4 call
control (simplex calls)
Power control and Frequency control
Frequency handoff
RF loopback control (TT)
Display of mobile information
Demodulated and channel decoded data
Protocol history display
Talk back, silence and test tone (1 kHz digitally
encoded)