beautypg.com

Specification – Atec Aeroflex-3920B User Manual

Page 12

background image

• Tx Ref Oscillator

• Tx Power

• Tx Modulation Balance

• Tx BER

• Tx FSK Error

• Tx Magnitude Error

• Tx Symbol Deviation

Technisonics Type 1 Radio Auto-Test/Alignment
(390XOPT614)
This option adds the capability to complete a fully automatic test and
alignment on Technisonics Type 1 radios. This option provides the
same functionality of the ASTRO Series radio Auto-Test/alignment
software, but for the Technisonics Type 1 radios.

Technisonics Type 2 Radio Auto-Test/Alignment
(390XOPT615)
This option adds the capability to complete a fully automatic test and
alignment on Technisonics Type 2 radios. This option provides the
same functionality of the ASTRO 25 Series radio Auto-Test/align-
ment software, but for the Technisonics Type 2 radios.

TX Tests

• Frequency

• Power

• CTCSS

• Microphone sensitivity

• Modulation limiting

• Audio distortion

• Audio frequency response

• FM hum and noise

RX Tests

• Audio distortion

• Audio sensitivity

• Audio frequency response

• Usable sensitivity

• Displacement bandwidth

• Audio squelch sensitivity

• Audio squelch blocking

• Hum and noise

Test High/Low or both power level settings on any channel with
support for a PTT line to auto-key/de-key the transmitter. Single
channel test execution is allowed to re-check failed channels. Supports
re-test, accept failure or abort on any failed test. Supports store and
recall for test configurations and test results. Network or local printer
support allows for an immediate hard copy to be obtained.

DMR Repeater Auto-Test (390XOPT626)
With the DMR repeater auto-test, the 3920B can automatically

perform the key transmitter and receiver tests for DMR Repeaters.
This test does not require the DMR repeater to be in any special test
mode, but can quickly make these measurements on any channel pro-
grammed into the repeater. The user simply indicates the frequencies
that the repeater is using from the auto-test setup screen, and then
can initiate the test and walk away. The testing is all performed com-
pletely automatically

SPECiFiCATiOn

RF SiGnAl GEnERATOR

SPECTRAl PURiTY

FREQUENCY

Range

10 MHz to 1.05 GHz (Standard) (Usable from

100 kHz)

10 MHz to 2.7 GHz (392XOPT058) (Usable

from 100 kHz)

Resolution

1 Hz

Accuracy

Frequency standard ±1 count

OUTPUT LEVEL

Range

T/R Port: -130.0 to -30.0 dBm (-30 dBm max

for CW or FM; -35 dBm max for AM modula-

tions; -40 dBm max for complex modulations)
Duplex: -130.0 to +10.0 dBm (+10 dBm max

for CW or FM; +5 dBm max for AM modula-

tions; 0 dBm max for complex

modulation)

Resolution

0.1 dB

Accuracy

1.0 dB for levels >-110 dBm (Typical better

than 0.6 dB)
1.5 dB for levels ≤-110 dBm (Typical better

than 1.0 dB)

Residual FM

<5 Hz (300 Hz to 3 kHz bandwidth)

Residual AM

<0.1% RMS (300 Hz to 3 kHz bandwidth)

Harmonics

<-25 dBc (Typically -30 dBc, RF level set at

+10 dBm)

Non-Harmonics

<-55 dBc (all freq. except Crossovers)
<-35 dBc (At 2nd order crossover frequency)
(10 MHz to 1 GHz: Crossover = 1400 MHz -

Gen freq.)
(1 GHz to 2.7 GHz: Crossover = 3400 MHz -

Gen freq.)
(Tracking Gen: Crossover = 3410.7 MHz -

Gen freq.)

Phase Noise

<-110 dBc/Hz @ 10 kHz offset, RF <500

MHz)
<-106 dBc/Hz @ 10 kHz offset, RF ≤1000

MHz)
<-95 dBc/Hz @ 10 kHz offset, RF >1000

MHz