beautypg.com

Atec Acterna-TTC-209OSP User Manual

Page 3

background image

3

TDR Measurement Option

This option locates copper faults. The

T-BERD Outside PlantTester can be easily

configured for TDR measurement by

selecting the cable type and approxi-

mate cable length being used. By

completing these simple steps, the

cumbersome process of determining

complex constants such as pulse width

and pulse height is avoided. Once the

TDR is set up, the graphical display

on the mainframe front panel allows the

user to immediately view the TDR traces.

A built-in zoom feature facilitates fault

identification by focusing on copper

faults such as bridged taps, splits, load

coils, high-resistance opens, and bad

splices.Faultidentificationisperformed

at the push of a button, with the distance

to the fault displayed in feet.

Turn Up and Troubleshoot

FT1/T1 Circuits

The T-BERD Outside Plant Tester

mainframe features a full-span T1

transmitter and receiver used to

identify marginal troubles with all

standard T1 stress patterns at various

output levels. Automatic configuration

and results with summary functions

immediately identify the presence of

T1 pulses, pattern, framing, and error

status. Additionally, the mainframe

can qualify T1 spans with automated

MULTIPAT

and BRIDGTAP

stress

patterns. To stress the entire T1 span

and verify the error tolerance of

network equipment, the T-BERD

Outside Plant Tester can insert bit

errors and BPVs.

Fractional T1 (FT1) Option

This option enables the T-BERD

Outside Plant Tester to perform BER tests

on selected channels in order to verify

transmission on contiguous and non-

contiguous FT1 bandwidth. It also

allows the technician to verify VF

circuit performance with 404, 1004,

2804, and 2713 Hz tones at various

output levels.

Standard T1/FT1 BER testing provides

the most accurate measure of point-

to-point transmission performance

by stress-testing the circuits to

ensure proper circuit configuration.

The advanced software options that

complement T1/FT1 BER testing

include: Advanced Stress Patterns

Option, Channel Monitor Option,

Enhanced ESF Option and Smart

Loopback/Command Codes Option.

Advanced Stress Patterns Option

This option enables the technician to

stress repeatered T1/FT1 circuits with

a variety of stress patterns such as

55 octet, T1-DALY, and other long user

patterns as recommended by the

ANSI T1.403 standard.

Channel Monitor Option

With this option, the T-BERD Outside

Plant Tester is able to simultaneously

monitor ABCD bits of all 24 timeslots,

listen to voice quality, and view the

data bits of individual DS0 channels.

Enhanced ESF Option

This option adds testing flexibility

to the T-BERD Outside Plant Tester.

It enables the T-BERD Outside Plant

Tester to decode ESF one-second

broadcastperformance reportmessages

(PRMs) to verify remote in-service

circuit performance. With this option,

the T-BERD Outside Plant Tester can

also emulate ANSI T1.403-compatible

CSU equipment to verify proper opera-

tion during circuit installation and fault

isolation as well as query performance

monitoring NIU equipment to retrieve

in-service performance data to verify

remote circuit operation. This option

supports Westell

equipment.