5
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
© 2013, AFL, all rights reserved. FLX3-3X-2000 Revision 1C 2013-09-30
Specifications are subject to change without notice.
OTDR (POINT-TO-POINT, PON, LIVE PON)
Emitter Type
Laser
Safety Class
Class 1 FDA 21 CFR 1040.10 and 1040.11, IEC
60825-1: 2007-03
Fiber Type
Single-mode
Available Wavelengths
1310 / 1490 / 1550 / 1625 / 1650 nm
Wavelength Tolerance
±20 / ±20 / ±20 / ±10 / ±10 nm
Dynamic Range (SNR=1)
b
41 / 38 / 41 / 38 / 38 dB (20 µs pulse)
22 / 19 / 22 / 19 / 19 dB (100 ns pulse)
Event Dead Zone
c
0.8 m
Attenuation Dead Zone
d
2.5 m
PON Dead Zone
e
30 m
Pulse widths
5, 10, 30, 100, 300 ns; 1, 3, 10, 20 µs
Range Settings
250 m to 240 km
Data Points
Up to 30,000
Data Point Spacing
5.0 cm (range <1.5 km);
Range/30,000 (range >1.5 km)
Group Index of Refraction
1.4000 to 1.7000
Distance Uncertainty (m)
±(1 + 0.005% x distance + data point spacing)
Linearity
±0.05 dB/dB
Trace File Format
Telcordia SR-4731 Issue 2
Trace File Storage Medium
4 GB internal memory (>1000 traces)
Data Transfer to PC
USB cable or Bluetooth
®
wireless
PON OTDR Modes
To Splitter, Through Splitter, Expert
Standard OTDR Modes
Full Auto, Expert, Real Time
OPTICAL POWER METER
Calibrated Wavelengths
1310, 1490, 1550, 1625, 1650 nm
Detector Type
InGaAs
Measurement Range
+23 to -50 dBm
Tone Detect Range
+3 to -35 dBm
Wavelength ID Range
+3 to -35 dBm
Accuracy
h
±0.25 dB
Resolution
0.01 dB
Measurement Units
dB, dBm or Watts (nW, µW, mW)
PON POWER METER FOR SINGLE-MODE ONLY
Calibrated Wavelengths
1490, 1550 nm
Detector Type
Filtered InGaAs
Isolation
>40 dB
Measurement Range
+23 to -50 dBm
Accuracy
g
±0.5 dB
Resolution
0.01 dB
Measurement Units
dBm or Watts (nW, µW, mW)
OPTICAL LASER SOURCE (OLS)
Emitter Type, Safety Class
Class I, FDA 21 CFR 1040.10 and 1040.11,
IEC 60825-1: 2007-03
Fiber Type
Single-mode
Available Wavelengths
1310, 1490, 1550, 1625, 1650 nm
Wavelength Tolerance
±20 nm (1310/1490/1550)
±10 nm (1625/1650)
Spectral Width (FWHM)
5 nm (maximum)
Internal Modulation
270 Hz, 330 Hz, 1 kHz, 2 kHz, CW
Wave ID (one, two, or three
wavelengths)
Compatible with NOYES Optical Power Meters
and Light Sources
Output Power Stability
f
±0.2 dB
Output Power
-1 dBm ±1.5 dB
VISUAL FAULT LOCATOR (VFL)
Emitter Type
Visible red laser, 650 ±20 nm
Safety Class
Class II FDA 21 CFR 1040.10 and 1040.11,
IEC 60825-1: 2007-03
Output Power (nominal)
0.8 mW into single-mode fiber
Modes
CW, 2 Hz flashing
GENERAL
Size (in boot)
20.1 x 13.0 x 5.3. cm (7.9 x 5.1 x 2.1 in)
Weight
0.8 kg (1.8 lb)
Operational Temperature
-10 °C to +50 °C, 0 to 95 % RH (non-condensing)
Storage Temperature
-20 °C to +60 °C, 0 to 95 % RH (non-condensing)
Power
Rechargeable Li-Ion or AC adapter
Battery Life
13.5 hours, Telcordia test conditions
12.5 hours, backlight on, continuous test
Display
LCD, 320 x 240, 3.5 in (89 mm), color,
high-contrast transflective with backlight
and AR coating.
Specifications
a
Notes:
a. All specifications valid at 25 °C unless otherwise specified.
b. Measured using 240 km range, 20 µs pulse and 3 min averaging.
c. Typical distance between the two points 1.5 dB down each side of a reflective
spike caused by a -45 dB event using 5 ns pulse width.
d. Typical distance from the location of a -45 dB reflective event to the point
where the trace falls and stays within 0.5 dB of backscatter,
using a 5 ns pulse width.
e. Typical distance from the start of a 1x16 splitter (13 dB loss) to the point
where the trace falls and stays within 0.5 dB of backscatter, using a 100 ns
pulse width with high resolution.
f. Over 8 hours.
g. At calibration wavelengths and power levels of approximately -5 dBm for
1550 nm and -10 dBm for 1490 nm.
h. At 1310/1550 nm wavelengths with CW power level of approximately
-10 dBm.
FLX380-30x FlexTester
3
OTDR