Otdr – Atec AFL-Noyes-FLX3 User Manual
Page 3
3
www.AFLglobal.com or (800) 321-5298, (603) 528-7780
© 2013, AFL, all rights reserved. FLX3-3X-2000 Revision 1C 2013-09-30
Specifications are subject to change without notice.
FLX380 MODELS
FEATURES
-300
-302
-303
-304
Compatible with all NOYES optical power meters and laser sources, including tone and Wave ID features
Compatible with NOYES optical fiber identifiers (OFI)
Integrated high-power optical power meter with Wave ID and tone detection
Integrated Visual Vault Locator (VFL with visible red laser)
1310 nm – OTDR, PON OTDR, laser source (CW, Wave ID, tone generation)
1550 nm – OTDR, PON OTDR, laser source (CW, Wave ID, tone generation)
1490 nm – OTDR, PON OTDR, laser source (CW, Wave ID, tone generation)
1625 nm – FTTx Live PON OTDR with 1625 nm filtered detector for in-service PON testing
1650 nm – FTTx Live PON OTDR with 1650 nm filtered detector for in-service PON testing
FTTx PON Power Meter (Detects and measures downstream 1490 and/or 1550 nm PON power levels)
Features and Applications by Model
FLX380 MODELS
FIBER TESTING APPLICATIONS
-300
-302
-303
-304
Point-to-point fiber optic cable installation test and troubleshooting
Verify end-to-end length, loss and return loss. Verify splice and connector loss and reflectance. Locate source of excess loss and/
or reflections, including micro- or macro-bends.
FTTx PON construction test
Test to or through splitters. Verify end-to-end length, loss and return loss. Verify splitter, splice and connector loss and
reflectance. Locate source of excess loss and/or reflections, including micro- or macro-bends.
a
FTTx customer fiber troubleshooting – dark fibers
Locate cable cuts, open splices, micro- or macro-bends and bad connections
FTTx in-service (Live PON) troubleshooting
Automatically detect live PONs. Prevent service-disrupting 1310/1550 nm OTDR tests on live PONs. Locate macro bends, poor
splices or high-loss connections without disrupting service to active PON subscribers.
FTTx service turn-up (commissioning)
Verify PON power levels at the ONT (subscriber) location. Locate faults in distribution or drop cables, or between splitters in
PONs built using distributed splitter architecture, all without disrupting service to active PON subscribers.
Note:
a. Adds 1490 nm OTDR and OLS. Testing at 1310 / 1550 nm is recommended and typically all that is needed to test FTTx PONs during construction.
FLX380-303 and -304 models
FLX380-300 and -302 models
FLX380-303,
304
FLX380-300,
-302
Visual Fault Locator
Visual Fault Locator
Optical Power Meter
Optical Power Meter
Dark Fiber OTDR
Dark Fiber OTDR
Live Fiber OTDR
PON Power Meter
Laser Source
Laser Source
FLX380-30x FlexTester
3
OTDR