3. Installation
22
031-103-B0-003 Rev. C
© 2002
TM
Tools List:
1" Socket (3/8" drive)
3/8" Rachet
#2 Phillips Screwdriver
Zip Tie Gun
1). Install SPI by tightening the attached
coaxial connector to the equipment tray.
2). Secure SPI ground wire to the SPI with
attached screw, and connect to enclosure
ground bar.
3). Terminate stripped end of wire at enclosure
ground bar.
3.4
Coaxial Cable to Service Power Inserter (SPI) Installation
3.4.1
SPI to Ground Bar Connection Procedure
Figure 3-10; Connector Fitting in Rear of Equipment Tray
Figure 3-12; SPI Ground Wire Connected to Enclosure Ground Bar
Figure 3-11; Location of SPI in Equipment Tray