3 dip-switch settings – ABUS SG1810 Profiline sounder User Manual

Page 15

background image

15

6.3 DIP-switch

settings

CONFIG configuration Description

CONFIG: 1
(Default: OFF)

Defines the operation of the trouble output (TRBL).

ON: Switches in the event of battery faults (low
voltage or charging fault), input voltage or sounder
faults.
OFF: Switches only for battery faults (low voltage or
charging fault).

CONFIG: 2
(Default: OFF)

The OFF setting must not be changed!

CONFIG: 3
(Default: OFF)

Defines the maximum sounder duration.

ON: 5 minutes
OFF: 3 minutes

IMPORTANT:

The sounder activation always ends if there is no
longer a trigger signal at the C+/C- connectors!

CONFIG: 4
(Default: OFF)

Defines the sounder sound.

ON: Slow
OFF: Fast

Configuration ID1

Description

ID1: 1-3
(Default: All OFF)

Not used.

ID1: 4
(Default: OFF)

Selection of sounder signal according to French
Standard NFA2P.

ON: French Standard
OFF: Normal Standard