Maintenance and repair

U

D

s

1

f

1

7.2.2 Air fi ltering

Fig. 10 Air fi ltering

D

Suction fl ange

f

1

Mesh

fi lter

s

1

Screws

U

Gas ballast valve

NOTICE

Insuffi cient maintenance on the air fi lter
The power of the machine lessens and damage may
occur to the machine.

Intake air fi lter:
The mesh fi lter (Fig. 10/f

1

) must be cleaned by rins-

ing out or purging or replaced more or less often
depending on how dirty the discharged medium is.
Remove the suction fl ange (Fig. 10/D) after undoing
the screws (Fig. 10/s

1

).

Also check the valve seating for contamination.
Assemble in reverse order.

WARNING

Risk of injury when handling compressed air
When blowing through with compressed air, solid
particles may be carried along or powder dust swir-
ling around may cause injury to the eyes.
Therefore, when cleaning with compressed air always