Installation

b) When connecting a circulating cooling system to

an external cooling system, it must be fi lled with
cooling fl uid.

NOTICE

Rinse the pipe network on the customer side
before connecting it
A fi lter element must be installed in the pipe net-
work to prevent foreign bodies getting into the heat
exchanger.

Risk of frost damage in the cooling system
Freezing cooling water may lead to extensive dam-
age to the machine. Therefore mix the cooling water
with at least 10 % of anti-freeze. The amount of
anti-freeze used must be adjusted to the ambient
climatic conditions.

Handling anti-freeze
Anti-freeze may contain harmful ingredients, such
as ethylene glycol that could damage your health,
especially if swallowed.

5.5

Filling with lubricating oil

a) Fill the lubricating oil (for suitable sorts see

„Maintenance“) for the gear teeth and the bear-
ings into the oil fi lling points (Fig. 2/H, 2/H

1

) up

to the middle of the inspection glasses (Fig. 2/
I, 2/I

1

).

b) Close the oil fi lling points.