beautypg.com

Available sizes, Materials pressure ratings – Cla-Val 100-22 600 Series User Manual

Page 2

background image

Epoxy Coating - suffix KC
This option NSF 61 Listed and FDA
approved, fusion bonded epoxy coating
is for use with cast iron, ductile iron or
steel valves. This coating is resistant to
various water conditions, certain acids,
chemicals, solvents and alkalies. Epoxy
coatings are applied in accordance with
AWWA coating specifications C116-03.
Do not use with temperatures above 175° F.

Viton

®

Rubber Parts - suffix KB

Optional diaphragm, disc and o-ring fabri-
cated with Viton

®

synthetic rubber.

Viton

®

is well suited for use with mineral

acids, salt solutions, chlorinated hydro-
carbons, and petroleum oils; and is pri-
marily used in high temperature applica-
tions up to 250° F. Do not use with epoxy
coating above 175°F.

For assistance in selecting appropriate
valve options or valves manufactured
with special design requirements,
please contact our Regional Sales
Office or Factory.

6" Globe, Flanged

4" Globe, Flanged

6" Angle, Flanged

Options

Specifications

Model 100 - 22

Operating Temp. Range

Available Sizes

Pattern

Flanged

Globe

4" - 24"

Angle

4" - 6 - 8"

Fluids

-40° to 180° F

Component

Standard Material Combinations

Body & Cover

Ductile Iron

Cast Steel

Bronze

Available Sizes

4" - 24"

4" - 16"

4" - 16"

Disc Retainer &
Diaphragm Washer

Cast Iron

Cast Steel

Bronze

Trim: Disc Guide,
Seat & Cover Bearing

Bronze is Standard

Stainless Steel is optional

Disc

Buna-N

®

Rubber

Diaphragm

Nylon Reinforced Buna-N

®

Rubber

Stem, Nut & Spring

Stainless Steel

For material options not listed, consult factory.
Cla-Val manufactures valves in more than 50 different alloys.

Materials

Pressure Ratings

(Recommended Maximum Pressure - psi)

Valve Body & Cover

Pressure Class

Flanged

Grade

Material

ANSI

Standards*

150

Class

300

Class

ASTM A536

Ductile Iron

B16.42

250

400

ASTM A216-WCB

Cast Steel

B16.5

285

400

ASTM B62

Bronze

B16.24

225

400

Note:

* ANSI standards are for flange dimensions only.

Flanged valves are available faced but not drilled.

Valves for higher pressure are available; consult factory for details