Type PZD/PZi-32/52 High Capacity Models
3
Available Only in Programmable Models
(See page 8 for Direct Connection of pH and Residual Chlorine Control Instruments)
Type PZiG Programmable Large Volume Models
PZD Series pumps offer higher capacities. These models feature
an extra large keyboard and the injection rate can be entered
directly in milliliters per minute.
The injection rate can be set three ways by direct entry of:
– Stroke speed: 1 to 300 spm
– Percentage: 1 to 100%
– Injection rate: ml/min.
• Onboard calibration measures the
actual discharge volume under the exact
operating condition of the specific installation and chemical,
then stores that value to insure the correct injection rate.
High Capacity models are
available in material codes
VFC, VEC, SS and FTC only.
VFC model is shown.
PZiG
with VTCF
Liquid Head
• Manual stroke length adjustment
20% to 100%.
• Set points can be easily viewed
on the LCD.
• Pump head may be rotated to
face in any of the three positions
other than where the keypad
and display are located.
• Pump head can be decoupled
from the controller base for
remote mounting.
PZiG Models offer capacities typically requiring motor driven pumps. Special models
easily handle viscosities of 1000 CPS (up to 4000 CPS at reduced volume).
Powerful onboard controls allow proportional flow rate, pH and residual chlorine control
by direct analog connection eliminating the PID Controller and Inverter (plus the control
panel to house them), that are required by similar sized motor driven pumps.
The injection rate can be set three ways by direct entry of:
– Stroke speed: 1 to 300 spm
– Percentage: 1 to 100%
– Injection rate: ml/min.
• Manual stroke length adjustment 20% to 100%.
Control Functions also include (see pages 8 & 9):
• Onboard calibration measures the actual discharge volume under the
exact operating condition of the specific installation and chemical, then stores
that value to insure the correct injection rate.
• Multi-pump proportional flow rate injection from
a single direct flowmeter signal (pulse/analog).
• Two point level switch control (see page 9)
Note: Install a pulsation
dampener for discharge lines
greater than 7 feet to achieve
maximum pressure capability.
• Batch injection
• Interval injection
• Proportional control with shift and proportional band function.
• Two line LCD screen displays injection rate and/or operational progress.
TYPE & SIZE SELECTION CHART: PZiG
PROGRAMMABLE
MAX. CAPACITY
MAX. PRESSURE
DRAWING /
STROKE
MAX. POWER
AVG. POWER
MODEL
GPD
GPH
ML/MIN.
PSI
CURVE
LENGTH (MM)
(VA)
(WATTS)
PZiG-300
130
5.4
340
140
page 7
1.5
750
100
PZiG-500
200
8.4
530
100
page 7
1.5
750
100
PZiG-700
288
12.0
760
60
page 7
1.5
750
100
PZiG-1000
380
15.8
1000
45
page 7
1.5
750
100
PZiG-1300
495
20.6
1300
30
page 7
1.5
750
100
TYPE & SIZE SELECTION CHART: PZ / PZD / PZi4 / PZi8
MANUAL
EXTERNAL
PROGRAMMABLE
MAX. CAPACITY
MAX. PRES.
DWG./
STROKE
MAX. PWR.
AVG. PWR.
MODEL
INPUT MODEL
1
MODEL
1
GPD
GPH
ML/MIN.
PSI
CURVE
LENGTH (MM)
(VA)
(WATTS)
PZ-31-HP
2
PZi4-31-HP
2
PZi8-31-HP
2
10.5
0.44
28
220
page 7
1.0
200
15
PZ-31
PZi4-31
PZi8-31
12
0.5
30
140
page 7
1.0
200
15
PZ-61
PZi4-61
PZi8-61
24
1.0
60
115
page 7
1.0
250
18
PZ-12
PZi4-12
PZi8-12
38
1.6
100
60
page 7
1.0
250
18
PZD-32
PZi4-32
PZi8-32
137
5.7
360
45
page 7
1.5
500
30
PZD-52
PZi4-52
PZi8-52
204
8.5
540
30
page 7
1.5
500
30
NOTES:
1
PZi4 models include 2-meter cable with 4-pin connector on one end; PZi8 models include separate 2-meter signal cables, one each with 4-pin and 8-pin connector end.
2
High Pressure models are available as PZ-31, PZi4-31 or PZi8-31 only; available in FEC or SS only. Refer to Material Code Chart on page 4.
Head can be turned 90° to allow base to be
mounted to a vertical wall (-31 / -61 / -12 only).