Features, Model number selection – Pump Solutions Group Neptune Series PZ_PZi_PZiG Pulse Metering Pumps User Manual
Page 2
2
PZ
PZD
PZi4
PZi8
PZiG
• PZ Models (Speed only is adjustable from 15 to 300 SPM)
៚
—
—
—
—
Manual control
• PZD & PZi Models (Adjust speed 1 to 300 SPM plus stroke length adjustment
1
)
—
៚
៚
៚
៚
• Enter desired flow directly in ml/min.
—
៚
—
៚
៚
Calibration
• Calibrate pump flow to actual condition of chemical,
—
៚
—
៚
៚
function
pressure, viscosity, etc.
Control input
• External interlock (Examples: level switch, remote start, reset)
—
—
៚
៚
៚
Operation
• Indicates speed and status
—
—
៚
៚
៚
display
• Indicates speed, feed rate
2
, status and other operational data
—
—
—
៚
៚
• Pulse signal Frequency-divide 1/1 to 1/9999, Multiply 1 to 9999 (See pg.6)
—
—
៚
៚
៚
Signal input
3
• Analog signal Shift function, Proportional band function (See page 6)
—
—
៚
៚
៚
4-pin connector
• pH Control/Residual Chlorine Control (See page 8)
—
—
—
—
៚
• Alarm output (Level switch, injection monitor
2
)
—
—
—
៚
៚
Signal output
4
• Operation pulse signal (Synchronous pulse output for each stroke)
—
—
—
៚
៚
8-pin connector
• Operation progress signal (Time or number of strokes remaining in program)
—
—
—
៚
៚
Alarms
• Alarm display, output and action (run, pause or stop) can be selected
—
—
—
៚
៚
• Two point level control (See page 9)
—
—
—
៚
៚
• Power supply for flow checker
—
—
—
៚
—
Other
• Interval operation (Repeat cycle program, see page 9)
—
—
—
៚
៚
functions
ON time: 1 to 999999 minutes / OFF time: 1 to 999999 minutes
• Counter (Countdown batch injection, see page 9)
—
—
—
៚
៚
1 to 9999 strokes (X1, X10, X100, X1000)
• Head can be turned 90° to allow base to be mounted to a vertical wall
5
៚
—
៚
៚
—
NOTES: 1. PZi4 and PZi8 Models in sizes -31 / -61 / -12: 50% to 100% stroke length adjustment.
PZi4 and PZi8 Models in sizes -32 / -52 plus all PZD and PZiG Models: 20% to 100% stroke length adjustment.
2. PZi8 only when used with Flow Checker shown on page 5.
3. PZi4 has one analog input and one high speed digital pulse input; PZi8 and PZiG have one analog input and two high speed digital pulse inputs. See page 9.
4. Two separate configurable outputs, either open collector (alarm, error, run) or pulse (operational sync or end of cycle).
5. Sizes -31 / -61 / -12 only.
TYPE PZi8
(programmable)
TYPE PZi4
(automatic)
TYPE PZ
(manual)
MANUAL
EXTERNAL
PROGRAMMABLE
CONTROL
INPUT
INPUTS / OUTPUTS
Features
TYPE
MODEL NUMBER SELECTION –
The complete model number consists of three parts:
TYPE + SIZE + MATERIAL CODE
TYPE
– Specify PZ or PZD for manual control; specify PZi4 for external input; specify PZi8 for programmable models.
The largest models are the PZiG Series, available in full programmable type only.
SIZE
– Size code selects the capacities per the charts on page 3. Sizes -31, -61 and -12 are available for type PZ.
Higher capacity sizes -32 and -52 are available for type PZD. All five sizes are available for types PZi4 and PZi8.
The very high PZiG capacities are shown in a separate chart.
MATERIAL CODE
– Select from charts on page 4.
Example – The complete model for a pump with a Kynar liquid end with
Viton seals rated at 160 ml/min capable of accepting a 4-20mA input would be:
Type
PZi4
+ Size
-61
+ Material code
-FFC
The complete model number becomes
PZi4-61-FFC