Installation, Ff (fixed flange series) only, Ft (side outlet series) only – Infinity Drain FFAS 65 Install Instructions User Manual
Page 5: Instalación, Solo ft (side outlet series), Solo ff (fixed flange series)
5
Installation
1. Locate the waste line position. Typically
linear drains span a dimension from wall to
wall, against a wall or at a shower entrance.
FF (Fixed Flange Series) only:
2. Spread a prelimainary mortar bed across the
intended drain location. Set drain into mortar
bed. Connect the outlet section (D) to the
existing waste pipe (F) via 2” no hub connection
using a 2” DWV no hub rubber coupling (E). Allow
stainless steel channel (C) to sit onto subfloor.
FT (Side Outlet Series) only:
2. Connect the outlet section (D) to the
existing waste pipe (F) via 2” no hub
connection using a 2” DWV no hub rubber
coupling (E). Be sure to use integrated drain
supports to support the stainless steel
channel (C) at the desired height.
Note: When drain install is required to
be flush against the finished wall, backer
board will install over the 1” flange of the
drain body.
Instalación
1. Localize la posición de la línea de residuos.
Típicamente los drenajes lineales extienden
a una dimensión desde pared a pared, contra
una pared, o en una entrada del baño.
Solo FT (Side Outlet Series):
2. Conecte la sección de salida (D) a la tubería
de residuos existente (F) a través de 2” sin
conexión concentrado usando DWV ningún
acoplamiento elástico (E). Asegúrese de
utilizar un drenaje integrado para soportar el
canal de acero (C) a la longitud desea.
Solo FF (Fixed Flange Series):
2. Conecte la sección de salida (D) a la
tubería existente (F) vía 2” conexión sin
concentrador usando 2” DWV goma de
acoplamiento (E). Permita el canal de acero
(C) sentarse en el subsuelo.
Tenga en cuenta: Cuando el drenaje se
instale es necesario que este contra la
pared terminada, placa de cemento se
instalara sobre 1” brida del drenaje.
*Not provided by Infinity Drain kits
FIXED FLANGE (FF) SERES
(A) Top Grate –
EA/DA/MA/SA/LA
(B) Adjustable Feet
Liquid/Fabric
Waterproofing
(C) Bottom
Channel – FC 65
(D) Vertical Outlet
(E) Rubber Coupling*
(F) Waste Pipe
KEY
SIDE OUTLET (FT) SERIES
KEY
Liquid/Fabric
Waterproofing
(A) Top Grate –
EA/DA/MA/SA/LA
(B) Adjustable Feet
(C) Bottom
Channel – OC 65
(D) Side Outlet
(E) Rubber Coupling*
(F) Waste Pipe
(C) Bottom Channel – FC 65
(D) Vertical
Outlet
(E) Rubber
Coupling*
(F) Waste Pipe
FF Series
(C) Bottom Channel – OC 65
(D) Side Outlet
Drain
Supports
(E) Rubber Coupling*
(F) Waste Pipe
FT Series
- FFAS 125 Install Instructions FFTIF 65 Install Instructions FTED 25 Install Instructions FTDG 25 Install Instructions FTDG 65 Install Instructions FTMN 25 Install Instructions FTAS 25 Install Instructions FTAS 65 Install Instructions FTTIF 65 Install Instructions FXED 65 Install Instructions FXDG 65 Install Instructions FXMN 65 Install Instructions FFED 25 Install Instructions FFED 65 Install Instructions FFDG 25 Install Instructions FFDG 65 Install Instructions FFMN 25 Install Instructions FFMN 65 Install Instructions FF AS 25 Install Instructions