Symbol definitions, Command/response table for sis commands, Remote control, cont’d – Extron Electronics SW RGBHV Series User Guide User Manual
Page 33

Remote Control, cont’d
SW RGBHV Series Switchers • Remote Control
4-4
Command/Response table for SIS commands
Command
ASCII Command Response
Additional description
(host to switcher)
(switcher to host)
Input selection
Select video and audio input
X1
!
In
X1
•All
Select input
X1
video and audio.
Example (SW4 RGBHV A):
3!
In3•All
Select input 3 video and audio.
Example (SW6 RGBHV):
5!
In5•All
Select input 5 video.
Select video input only
X1
&
In
X1
•Vid
Select input
X1
video only (audio
breakaway).
Select audio input only
X1
$
In
X1
•Aud
Select input
X1
audio only
(SW 2/4/6 RGBHV A only)
(audio breakaway).
Input signal sensing
Request all inputs’ status
0S
Sig•
X2
1
•
X2
2
•...•
X2
n
Each
X2
response is the signal
status of an input, starting from
input 1; n is the maximum number
of inputs for this model.
Example (SW6 RGBHV):
0S
Sig•1•1•1•0•1•0
The input signal is present on
inputs 1, 2, 3, and 5. No signal is
present on inputs 4 and 6.
Request an individual input’s status
X1
S
X2
X1
’s signal status =
X2
.
ASCII to HEX Conversion Table
Space
Symbol definitions
Input and output numbers in commands may be entered as either 1-, 2-, or
3-digit numbers. All input and output numbers are specified as 3-digit
numbers in the response.
=
CR/LF (carriage return/line feed) (0x0D 0A)
=
CR (carriage return, no line feed)
•
=
space
X1
=
Input number
1 through the maximum number of inputs
X2
=
Input signal status
0 = no signal detected, 1 = signal detected
X3
=
On/off
0 = off, 1 = on
X4
=
Numeric value
-18 dB to +24 dB, each step = 1 dB
X5
=
Audio gain
0 through 24
X6
=
Audio attenuation
1 through 18
X7
=
Controller firmware
x.xx
X8
=
Switch mode
1 = normal switch mode, 2 = autoswitch mode