Command/Response table for SIS commands

Command

ASCII Command Response

Additional description

(host to switcher)

(switcher to host)

Input selection

Select video and audio input

X1

!

In

X1

•All

Select input

X1

video and audio.

Example (SW4 RGBHV A):

3!

In3•All

Select input 3 video and audio.

Example (SW6 RGBHV):

5!

In5•All

Select input 5 video.

Select video input only

X1

&

In

X1

•Vid

Select input

X1

video only (audio

breakaway).

Select audio input only

X1

$

In

X1

•Aud

Select input

X1

audio only

(SW 2/4/6 RGBHV A only)

(audio breakaway).

Input signal sensing

Request all inputs’ status

0S

Sig•

X2

1

X2

2

•...•

X2

n

Each

X2

response is the signal

status of an input, starting from
input 1; n is the maximum number
of inputs for this model.

Example (SW6 RGBHV):

0S

Sig•1•1•1•0•1•0

The input signal is present on
inputs 1, 2, 3, and 5. No signal is
present on inputs 4 and 6.

Request an individual input’s status

X1

S

X2

X1

’s signal status =

X2

.

ASCII to HEX Conversion Table

Space

Symbol definitions

Input and output numbers in commands may be entered as either 1-, 2-, or
3-digit numbers. All input and output numbers are specified as 3-digit
numbers in the response.

=

CR/LF (carriage return/line feed) (0x0D 0A)

=

CR (carriage return, no line feed)

=

space

X1

=

Input number

1 through the maximum number of inputs

X2

=

Input signal status

0 = no signal detected, 1 = signal detected

X3

=

On/off

0 = off, 1 = on

X4

=

Numeric value

-18 dB to +24 dB, each step = 1 dB

X5

=

Audio gain

0 through 24

X6

=

Audio attenuation

1 through 18

X7

=

Controller firmware

x.xx

X8

=

Switch mode

1 = normal switch mode, 2 = autoswitch mode