Command/Response Table for SIS commands
Command
ASCII (Telnet)
(host to switcher)
Response
(switcher to host)
Additional description
Input Selection
Select video and
audio
X!
!
In
X!
All
]
Select input
X!
video and audio.
Select video only
X!
&
In
X!
Vid
]
Select input
X!
video only.
Select audio only
X!
$
In
X!
Aud
]
Select input
X!
audio only.
Auto Switch
Normal switch mode
1#
F1
]
Set switch mode to normal.
Auto switch mode
2#
F2
]
Set switch mode to auto.
Input video sensing
Request all inputs’
status
Example: (SW8)
0S
0S
Sig•
X@
•
X@
...
X@]
Sig•1•1•1•1•0•1•1•0
]
Each
X@
response is the signal status
from each input
X!
’s signal status.
The input signal is present on inputs
1,2,3,4,6, and 7. No signal is present
on inputs 5 and 8.
Request specific
input’s status
X!
S
X@]
X!
’s signal status =
X@
.
Video mute
N
These commands mute and unmute both video outputs.
Mute video
1B/b
Vmt
X#]
Video mute on.
Unmute video
0B/b
Vmt
X#]
Video mute off.
Read mute status
B/b
X#]
Video mute status.
Audio mute
N
These commands mute and unmute both audio outputs.
Mute audio
1Z/z
Amt
X#]
Audio mute on.
Unmute audio
0Z/z
Amt
X#]
Audio mute off.
Read mute status
Z/z
X#]
Audio mute status.
Output Volume Control (variable audio output)
Set audio volume to
a specific level
Example:
X$
V
75V
Vol
X$]
Vol75
]
Sets output volume to 75.
Increment volume
+V
Vol
X$]
Decrement volume
-V
Vol
X$]
View volume
V
X$]
VSW I AAP Compatibility Mode
Enable/disable
single input
EX!
*
X#
VSWE
}
Vswe•
X#
•
X#
•
X#
......•
X#]
X!
is an input (1-8 or 1-12).
Enable/disable all
inputs
E
0*
X#
VSWE
}
Vswe•
X#
•
X#
•
X#
......•
X#]
X#
is the enabled/disabled status
from each input (0 = disabled,
1 = enabled).
View current status
E
VSWE
}
Vswe•
X#
•
X#
•
X#
......•
X#]
Front panel lockout
Turn front panel
lockout on
1X/x
Exe
X#]
Front panel lockout on.
Turn front panel
lockout off
0X/x
Exe
X#]
Front panel lockout off.
View front panel
lockout status
X/x
X#]