2-13

SW8/12 VGA Ars • Installation and Operation

Front Panel

The SW8/12 VGA Ars switcher front panel controls are described below.

ACTIVE

SW8 VGA Ars

1

2

3

4

5

6

7

8

AUTO SWITCH

MODE

NORMAL

AUTO

1

3

2

4

5

Figure 2-17 — SW8 VGA Ars front panel

AUTO SWITCH

ACTIVE

MODE

NORMAL

AUTO

SW 12 VGA Ars

1

2

3

4

5

6

7

8

9

10

11

12

1

3

2

4

5

Figure 2-18 — SW12 VGA Ars front panel

a

Auto switch active LED — Lights when the auto switch mode is enabled.

b

Input buttons and LEDs— Depending on the model there are eight or twelve

input buttons and corresponding LEDs. To select an input, press the desired

input button. The adjacent LED lights.

c

Mode (Input 1) button — The Mode button functions in conjunction with

other buttons as shown in the table below. Mode is a secondary function of

the Input 1 button.

Hold

Press

Description and Result

Mode

Normal

Enable Normal mode —

Front panel input buttons operate normally.

Auto Switch Active LED is off.

Mode

Auto

Enable Auto switch mode

Front panel input buttons are locked out.

Switcher outputs highest number input that has a sync signal present. If

no sync signal is present, input #1 is selected by default.

Auto Switch Active LED is on.

Mode

Input button

#4 for 3 sec.

Enable/disable Executive mode

All LEDs flash 3 times. All front panel

input buttons are locked out. Attempts to select an input button causes

all LEDs to flash.
Input selections via RS-232 and VSW IAAP still function.
Disable Executive mode

All LEDs flash three times, and the front

panel input buttons return to operation.

Mode - while applying

power

Perform factory reset

Reset unit to its factory settings.

d

Normal (Input 2) button — Hold Mode and press Normal to have the front

panel input buttons operate in manual mode - press an input button to select