Connect the Priority Page Controller to

the Vol/Mute port on the switcher

5

. Close and latch the top of the Priority Page Sensor.

Reconnect the speaker cable to the speaker.

6

. Cut an 18" (45 cm) section from the unterminated end of the

supplied blue sensor cable. Use it to connect the Relay Out

port on the Priority Page Controller to the Mute and Ground

pins on the PoleVault PVS 204SA Vol/Mute port (see the

figure at right). Polarity need not be observed.

N

Do not connect either of the outputs from the

Priority Page Controller to the 10V port on

the PVS 204SA switcher. The output relay must

connect only to the PVS 204SA switcher and not

to a MediaLink controller.

7

. Strip 3/16" of insulation from each conductor on the bare

wire end of the remaining blue sensor cable. Do not tin the

leads. Feed the wire into the junction box (clamping it down

if necessary) and connect the wires to the 2-pole captive screw

connector on the Priority Page Sensor. Polarity need not be

observed.

8

. Route the connector end to the Priority Page Controller, and

plug it into the Paging Sensor receptacle.

POWER

C NO

PAGING

SENSOR

OUT

TIME

RELAY

SENSITIVITY

12V

0.5A MAX

ON

1 2

Page
Sensor

Priority Page
Controller

7

Wire the connector on the Page sensor

and

8

connect it to the Paging Sensor

port on the Priority Page Controller.