Remote Control

This section covers topics relating remote control operation, including:

Output Control

RS-232 Control

Contact Closure Control

The rear panel Remote connectors of the switcher can be connected to the serial port output
of a host device such as a computer or control system, or to a contact closure device such
as the Extron MMX 32 AAP panel (part number 70-277-11) or MMX 32 MAAP panel (part
number 70-277-12 or -22). The contact closure connectors are two 5-pole captive screw
connectors, which control outputs 1 and 2 separately.

REMOTE

RS-232

+5V

2

1

1 2 3

Tx Rx

CONT

AC
T

Output 1 control

Output 2 control

RS-232
connection

Figure 12.

Remote Connectors Arrangement

Output Control

Momentarily short pin 1, 2, or 3 to ground to switch to that input. Use the +5 V port when
controlling the output with an MMX 32 AAP/MAAP panel.

RS-232 Control

The RS-232 connection makes software control of the switcher possible via the Extron
Simple Instruction Set (SIS) or the Extron Windows

®

-based control program. The RS-232

connector on the MMX 32 VGA MTP is a 3-pole captive screw connector.
The protocol for this connector is:
•9600 baud •8-bit •1 stop bit •no parity •no flow control

NOTE: For RS-232 connect transmit, receive, and ground connectors to control system