MMX 42/62 Series Matrix Switchers • Installation

Installation

MMX 42/62 Series Matrix Switchers • Installation

2-2

2-3

Installation Overview

To install and set up an Extron MMX 42/62 switcher for

operation, follow these steps:

1

Turn off all of the equipment. Ensure that the video

sources and the output display are all turned off and

disconnected from the power source.

2

Mount the switcher. See "Mounting the Switcher", below.

3

Attach the cables. See "Rear Panel Cabling" in this chapter.

4

Plug in the power supply, then turn on the display devices

and the input devices.

5

Set the audio gain and attenuation. See the "Set input

audio level" SIS commands in chapter 4, "Remote Control".

Mounting the Switcher

C

Installation and service must be performed by

authorized personnel only.

The 1-inch high, quarter-rack width switcher can be placed on

a tabletop, mounted on a rack shelf, mounted under a desk or

tabletop, or mounted on a projector bracket.

Tabletop placement

Affix the four included rubber feet to the bottom of the unit and

place it in any convenient location.

Rack mounting

For optional rack mounting, mount the switcher on any of the

following rack shelves:

RSF 123 3.5-inch deep rack shelf kit (part #60-190-20)

(figure 2-1, on the next page)

RSB 123 3.5-inch deep rack shelf (part #60-604-21)

RSU 126 6-inch deep universal rack shelf kit (part #60-190-10)

RSB 126 6-nch deep basic rack shelf (part #60-604-11)

RSU 129 9.5-inch deep universal rack shelf kit

(part #60-190-01) (figure 2-2, on page 2-4)

RSB 129 9.5-inch deep basic rack shelf (part #60-604-02)

(2) 4-40 x 3/16"
Screws

Use 2 mounting holes on
opposite corners.

RSF 123 3" Rack Shelf Kit

1/2 Rack Width Front
False Faceplate

Figure 2-1 — Mounting the switcher on a 3-inch rack
shelf

UL guidelines

The following Underwriters Laboratories (UL) guidelines

pertain to the installation of the matrix switcher into a rack.
1

.

Elevated operating ambient temperature — If the

equipment installed in a closed or multi-unit rack

assembly, the operating ambient temperature of the

rack environment may be greater than room ambient

temperature. Therefore, install the matrix switcher in

an environment compatible with the maximum ambient

temperature (TMA = 122 °F , +50 °C) specified by Extron.

2

.

Reduced air flow

— Install the equipment in a rack so that

the amount of air flow required for safe operation of the

equipment is not compromised.

3

.

Mechanical loading

— Mount the equipment in the rack

so that a hazardous condition is not achieved due to

uneven mechanical loading.

4

.

Circuit overloading

— Connect the equipment to

the supply circuit and consider the effect that circuit

overloading might have on overcurrent protection and

supply wiring. Appropriate consideration of equipment

nameplate ratings should be used when addressing this

concern.