MMX 42/62 Series Matrix Switchers • Remote Control

Remote Control

MMX 42/62 Series Matrix Switchers • Remote Control

4-2

4-3

The switcher’s rear panel Remote connector (figure 4-1) can be

connected to the serial port output of a host device. Remote

communications with the switcher are via the Extron Simple

Instruction Set or using the Windows-based Extron control

program.

DB9 Pinout (Female)

To control equipment

5

1

9

6

Rx

Tx

Gnd

Rx

Tx

Gnd

RS-232

3-pole

captive screw

connector/socket

Pin

RS-232

Function

1

2

TX

Transmit data (-)

3

RX

Receive data (+)

4

5

Gnd

Signal ground

6

7

8

9

Figure 4-1 — Remote connector pinout

The RS-232 protocol of the rear panel RS-232/Remote connector

is 9600 baud, 1 stop bit, no parity, and no flow control.

Simple Instruction Set Control

Host-to-interface communications

SIS commands consist of one or more characters per field. No

special characters are required to begin or end a command

character sequence. When a command is valid, the switcher

executes the command and sends a response to the host device.

All responses from the switcher to the host end with a carriage

return and a line feed (CR/LF = ]), which signals the end of the

response character string. A string is one or more characters.

Switcher-initiated messages

When a local event, such as a front panel operation or error

condition, occurs, the switcher responds by sending a message

to the host. The switcher-initiated messages are listed below:
(c) Copyright 2004, Extron Electronics MMX (42 or 62), Vx.xx,

60-nnn-nn]
The switcher issues the copyright message and the input

selected message when it first powers on. Vx.xx is the firmware

version number.
Outy•Inn•All]
Outy•Inn•Vid]
Outy•Inn•Aud]
The switcher sends the Outy•Inn message whenever the

selected input is changed using the front panel buttons. y is

the output number and n is the input number. All, Vid, or Aud

indicates both video and audio, video only, or audio only. The

power-up default is video and audio input 1 tied to output 1

and output 2.

Error responses

When the switcher receives a valid SIS command, it executes

the command and sends a response to the host device. If

the switcher is unable to execute the command because the

command is invalid or it contains invalid parameters, the

switcher returns an error response to the host. The error

response codes are:
E01 - Invalid input channel number (out of range)
E10 - Invalid command
E12 - Invalid output number (out of range)
E13 - Invalid parameter

Timeout

Pauses of 10 seconds or longer between command ASCII

characters result in a timeout. The command operation is

aborted with no other indication.