MMX 42/62 Series Matrix Switchers • Remote Control

Remote Control, cont’d

4-14

MMX 42/62 Series Matrix Switchers • Remote Control

4-15

Loading the firmware to the switcher

To load a new version of firmware to your MMX switcher,

call the Firmware Loader software from within the Universal

Switcher Control Program. Your computer’s serial port must

be connected to the switcher’s serial port. See chapter 2,

“Installation,” for more information.
1

.

If necessary, download the Firmware Loader installer

executable file to your computer, as follows:
a

. On the Extron Web site, click the Download tab.

b

. On the Download Center page, click Software on the

left sidebar menu.

c

. Locate the “Firmware Loader” line and click the

Download link at the far right.

d

. Follow the instructions on the download screens to

save the installer file to your computer.

e

. In Windows Explorer or another file browser, locate the

Firmware Loader executable file in your computer’s

file system and double-click on it to open it.

f

. Follow the instructions on the Installation Wizard

screens to install the Firmware Loader on your

computer. Unless you specify otherwise, the installer

program places the Firmware Loader file, “FWLoader.

exe” in C:\Program Files\Extron\FWLoader.

N

If the Extron and FWLoader folders do not yet exist in

your Program Files folder, the installer creates them.

2

.

In the Universal Switcher Control Program, click the tool

bar's Firmware Loader button (

).

N

If the Firmware Loader button does not appear in the

Universal Switcher Control Program window, the

Firmware Loader software is not installed.

3

.

If you have not previously updated firmware for the MMX

switcher before, on the Add Device screen (figure 4-11),

select the RS-232 tab.

If you have previously updated firmware for this model,

click Cancel. The Firmware Loader window appears.

Proceed to step 6.

N

Although the screen also has a TCP/IP tab, the switcher

does not have a LAN port. Do not select the TCP/IP tab.

Figure 4-11 — Add Device screen

4

.

From the drop-down menus on the RS-232 screen, select

the appropriate Com port number and baud rate (the

default is 9600).

5

.

Click OK. The Firmware Loader window appears

(figure 4-12).

6

Figure 4-12 — Extron Firmware Loader window

6

.

Select the MMX and click File > Open. The Choose

Firmware File screen appears (figure 4-13, on the next

page).