©2000 - INLINE, Inc.

IN2013HR Operation Manual - V1.0 12/05/00

Parts Included

(1) IN2013HR: Interface
(1) IN9230: IEC Power Cable (U.S. only)
(1) IN9333: Alignment Tool

(1) Operation Manual


Optional Accessories

Extension Cables

IN8400 Series: 13W3 Workstation Extension Cable (available in lengths from 6’ to 50’)

RGB Installation Cables

Coaxial Cables

3-Conductor

4-Conductor

5-Conductor

Standard Resolution

IN7000-4

IN7000-5

Standard Resolution, Plenum

IN7000P-4

IN7000P-5

Super High Resolution

IN7300-3 IN7300-4 IN7300-5

Super High Resolution, Plenum

IN7400P-5

Ultra High Resolution

IN7200-3 IN7200-5 IN7200-6

All cable grades are available in lengths from 3’ to 250’ pre-terminated with high quality BNC connectors or as bulk cable.


Troubleshooting



Problem: There is no image on the display device.

Œ Solution 1: Make sure that the IN9230 IEC power cable is securely plugged into the

unit and the A/C source.

Œ Solution 2: Make sure the A/C source is live.

Œ Solution 3: Verify that the power switch is turned on for the video source, the

IN2013HR and the display device.

Œ Solution 4: Verify the connections to the video source and the output display device(s).


Problem: The power switch is turned on, but the front panel LED is dark.

Œ Solution 1: Make sure that the IN9230 IEC power cable is securely plugged into the

unit and the A/C source.

Œ Solution 2: Make sure the A/C source is live.

Œ Solution 3: The IN2013HR contains a 0.5A / 250V time delay fuse. To change the

fuse, first remove power from the unit and then slide out the fuse holder (located on the
rear panel between the power switch and the IEC cable receptacle) using the IN9339
Alignment Tool (included).