Extron Electronics IN2013HR User Manual
Page 10
8
IN2013HR Operation Manual - V1.0 12/05/00
©2000 - INLINE, Inc.
OUTPUT SIGNAL FORMAT SELECTION
Output Format: Automatic Sense Mode (Dipswitch 5 = 1)
In factory default configuration, the IN2013HR automatically senses the number of cables connected
to the output BNC connectors and selects an appropriate output signal format. LED indicators located
next to the V/Sync, H/Comp Sync and Green output BNCs (on the back of the interface) provide clear
visual confirmation of the current output sync format. In order for output format auto sense circuit to
operate, dipswitch 5 on Switch Bank 1 must be set to 1.
Number of Cables Connected to Output
Output Format
(3) Cables connected to RGB BNCs
RGsB
(4) Cables connected to RGBS BNCs
RGBS
(5) Cables connected to RGBHV BNCs
RGBHV
Output Sync Format : Manual Mode (Dipswitch 5=0)
For some applications, you may wish to force the interface to operate in a specific output format.
To set the output sync format manually, you must first disable the auto sense circuit by setting
dipswitch 5 on Switch Bank 1 to 0. Next, set dipswitches according to the table below to select
the desired output format.
Output Format
Dipswitch Settings
(Switch Bank 1)
RGBHV (Factory Default)
2 = 0
3 = 1
5 = 0
RGBS 2
=
0
3 = 0
5 = 0
RGsB 2
=
1
3 = 1
5 = 0
7 = 1
Composite Monochrome on Green BNC
2 = 1
3 = 1
5 = 0
7 = 0
INPUT SIGNAL FORMAT SELECTION
The IN2013HR is set at the factory for automatic operation with SUN and most SGI computers
(*dipswitches 8 / 9 / 10 off). For other computers or signal formats, carefully set dipswitches 8, 9 and
10 as indicated in the chart below
.
INPUT SIGNAL CONFIGURATION - SWITCH BANK 1
DIPSWITCH SUN
RGBS*
SUN
RGBHV
SGI / NeXT
RsGsBs
SGI
RGBS
SGI
RGBHV
IBM
POWER
PC
8 0
1
0
0
1
0
9 0
0
0
1
0
1
10 0
1 1
1
0 0
*Factory Default Settings