IR 102 Remote Control Kit • Installation and Operation

Installation and Operation

IR 102 Remote Control Kit • Installation and Operation

1-2

1-3

UL requirements

The following Underwriters Laboratories (UL) requirements
pertain to the installation of the IR 102 Rx into or onto a rack.

1. Elevated

operating

ambient

— If the equipment is

installed in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment
may be greater than room ambient. Therefore, consider
installing the equipment in an environment compatible
with the maximum ambient temperature (Tma) specifi ed
by the manufacturer.

2. Reduced

air

fl ow

— Installation of the equipment in a rack

should be such that the amount of air fl ow required for
safe operation of the equipment is not compromised.

3. Mechanical

loading

— Mounting of the equipment in

the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.

4. Circuit

overloading

— Consideration should be given to

the connection of the equipment to the supply circuit and
the effect that overloading of the circuits might have on
over current protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be
used when addressing this concern.

5. Reliable

earthing

(grounding)

— Reliable earthing

of rack-mounted equipment should be maintained.
Particular attention should be given to supply connections
other than direct connections to the branch circuit (such as
the use of power strips).

Rack mounting instructions

1.

If rubber feet were previously installed on the bottom of
the remote receiver, remove them.

2.

Mount the remote receiver on the rack shelf, using two
4-40 x 3/16" screws in opposite (diagonal) corners to
secure the remote receiver to the shelf.

3.

Install blank panel(s) or other unit(s) to the rack shelf.

4.

Insert the shelf into the rack, aligning the holes in the shelf
with those of the rack.

5.

Secure the shelf to the rack using the supplied machine
screws. This shelf can be mounted in the front or in the rear
of the rack.

About the IR 102 Kit

The Extron IR 102 Kit is an infrared (IR) remote control kit that
can control a variety of Extron switchers and other devices via
RS-232 or contact closure. This kit contains the following items:
• (1) IR 102 handheld remote control
• (1) IR 102 Rx remote receiver
• (1) IR Sensor

Mounting the IR 102 Rx remote receiver

The IR 102 Rx remote receiver can be mounted on a rack shelf,
under a desk or tabletop, or on a projector bracket. There are
many optional accessories for mounting the IR 102 Rx, including
the following items:
• RSF 123 — 1U, 3.5" deep, VersaTools

®

rack shelf kit

(part #60-190-20)

• RSB 123 — 1U, 3.5" deep, basic VersaTools rack shelf

(part #60-604-20)

• RSU 126 — 1U, 6" deep, universal rack shelf kit

(part #60-190-10)

• RSB 126 — 1U, 6" deep, basic rack shelf (part #60-604-10)
• RSU 129 — 1U, 9.5" deep, universal rack shelf kit

(part #60-190-01)

• RSB 129 — 1U, 9.5" deep, basic rack shelf (part #60-604-01)
• MBU 123 mini under-desk mounting bracket kit

(part #70-212-01)

• VersaTools projector mounting kits — PMK 100 (part

#70-367-01), PMK 300 (part #70-374-01), and PMK 350 (part
#70-563-02, -03)

Rack mounting

For optional rack mounting, mount the IR 102 Rx remote
receiver on one of the rack shelves listed above. On the
standard 9.5" deep rack shelf, the remote receiver mounts in one
of four locations to the rear of the rack or in one of four locations
to the front of the rack.